beautypg.com

Alliance Laundry Systems Drying Tumblers 175 Pound Capacity User Manual

Page 20

background image

Page 17

TROUBLE

CAUSE

REMEDY

Check fuses on circuit breakers. Make sure main

control switch is ON.

Check power source: voltage, phase, and frequency

must be the same as specified on electrical rating

plate.

Turn timer clockwise to desired time setting.

Check wire connections in electrical box on rear of

dryer.

Check coils and contacts.

Check voltage at motor teminals. Voltage must be

within (plus or minus) 10% of voltage shown on

motor rating plate -- if not, check with local power

company for recommended corrective measures.

Check with local power company to insure that

wiring is adequately sized for load.

Check all electrical connections and tighten any

loose connections.

Refer to Installation Manual for recommended make-

up air openings.

Clean lint accumulation on and around motors.

Motors should not be covered with or filled with

lint.

Close door.

Adjust switch by removing cover and bend actuator

lever to clear switch button 3/8” with cover in

place.

Check continuity across switch with power off, in

closed and open switch. If no continuity, replace

switch.

Push in contactor trip button. If motor starts, check

voltage going to pull-in solenoid. If present,

replace contactor. If not, problem is before motor

contactor.

Confirm timer is working.

No power

Incorrect power

Time off

Loose wiring connections

Defective starting relay

Low voltage

Inadequate wiring

Loose connections

Inadequate air

Poor housekeeping

Loading door open

Door switch out of adjustment

Defective door switch

Defective basket motor contactor

Reversing timer

Motor will not start.

Motor tripping on

thermal overload.

Basket motor will not

run.

Basket will not reverse.

Troubleshooting Chart