Page 14

Troubleshooting Chart

TROUBLE

CAUSE

REMEDY

Replace V-Belt.

Adjust belt tension.

Tighten set screw.

Remove load.

Refer to Installation Manual for proper leveling

procedures.

Accidental damage to the fan blade can change the

dynamic balance. Damaged fans should be replaced.

Adjust basket clearance.

Tighten set screws; make sure sheaves are in proper

alignment.

Adjust belt tension.

Occasionally screws, nails, etc., will hang in the basket

perforations and drag against the sweep sheets

surrounding the basket. Such foreign objects should

be removed immediately.

Check for correct control voltage - 24V.

Check power supply, check secondary voltage on

transformer and check wiring and wiring diagram.

May be broken or defective high voltage lead. Module

not receiving correct input to ignite. Refer to Direct

Spark Ignition section. Make sure ignition module

ground wire is securely grounded to the machine (both

sides).

Check continuity across unplugged valve. If defective,

replace coil assembly.

Turn manual gas valve “ON”.

V-Belt broken

V-Belt loose

Motor Pulley loose

Basket overloaded

Not leveled

Fan out of balance

Basket rubbing

V-Belt sheaves

Belt

Foreign objects

Incorrect voltage

No voltage

Spark igniter not sparking

Defective gas valve

Gas turned off

Basket motor runs, but

basket will not revolve.

Dryer noisy or vibrating.

Dryer runs but no heat.

NOTE: This dryer has

two ignition systems,

valves, etc. Be sure to

check both systems.