Specially developed and suitable descal-
ing and cleaning tablets are available
from retailers or customer service.
Order number Retailer
Customer
service
Cleaning
tablets
TCZ6001
310575
Descaling
tablets
TCZ6002
310967
Important: If there is a water ilter in the
water tank (16), it must be removed before
starting the service programme.
To start the service programme, press and
hold the service button (12) for at least
5 seconds.
Information: The service button (12) lash
es while the programme is running.
LED
H
lights up.
● Empty the drip tray (8) and reinsert it.
The appliance rinses twice.
LED
G
lights up.
● Open the drawer (4).
● Drop a Bosch cleaning tablet into the
drawer (4) and close it.
● Press the start button (10).
LED
D
lights up.
● Fill the empty water tank (16) with luke
warm water up to the
0.5l mark and then
dissolve two Bosch descaling tablets in
this water.
● Press the start button (10).
The service programme will now run for
approximately 10 minutes.
LED
h
lights up.
● Place a container with a capacity of at
least 0.5 litres under the milk frother
outlet (6).
● Pull out the milk frother (6)
to open it.
The service programme will now run for
approximately 12 minutes.
LED
D
lights up.
● Rinse the water tank (16) and reill it with
fresh water up to the
max mark.
● Press the start button (10).
The service programme will now run for
approximately 30 seconds and rinse the
appliance.
LED
h
lights up.
● Push the milk frother (6) in to close it.
The service programme will now run for
approximately 8 minutes.
LED
H
lights up.
● Empty the drip tray (8) and reinsert it.
If you are using a ilter, reinsert it now.
The appliance has been cleaned, descaled
and is ready for use again.
TES501_1DE.indb 35