46-648 Jupiter Magnetostrictive Transmitters
1.6.4.1 Measurement Type: Level Only (cont.)
Display
Action
Comment
24
DispFact
(select)
Select Yes to display factory
parameter menus
25
History
(current status)
Enter to view history of
exceptions
Diagnostic Display
26
Run Time
Display only
Elapsed time since power on; reset to zero with History Reset
27
History
Reset
Press Enter and select yes to
clear history
28
Conv Fct
xxxxxx
Factory parameter
Do not adjust
29
Scl Ofst
Factory parameter
Do not adjust
30
F1Thresh
Factory parameter
Do not adjust
31
F1 Polar
Factory parameter
Do not adjust
32
Senstvty
Factory parameter
Do not adjust
33
Drv Ampl
Factory parameter
Do not adjust
34
ElecTemp
xxx C
Diagnostic Display
Present temperature in electronics compartment (degrees C)
35
Max Temp
xxx c
Diagnostic Display
Maximum electronics temperature recorded (degrees C)
36
Min Temp
xxx C
Diagnostic Display
Minimum electronics temperature recorded (degrees C)