beautypg.com

0 troubleshooting (continued) – Nova-Tech LMI Roytronic Series A Metering Pump User Manual

Page 38

background image

38

TROUBLESHOOTING

6.0 Troubleshooting (continued)

PROBLEM

POSSIBLE CAUSE

SOLUTION

Leakage at tubing

1. Worn tubing ends.

1. Cut about 1 in (25 mm) off tubing and

then replace as before.

2. Loose or cracked fitting.

2. Replace fitting if cracked. Carefully

hand tighten fittings.

DO NOT USE

PIPE WRENCH. An additional 1/8 or

1/4 turn may be necessary

3. Worn seal rings.

3. Replace balls and seal rings (see Sec-

tion 5.4)

4. Solution attacking Liquid Handling

Assembly

4. Consult your local distributor for alter-

nate materials.

Low Output or Failure

to Pump Against

Pressure

1. Pump’s maximum pressure rating is

exceeded by injection pressure.

1. Injection pressure cannot exceed

pump’s maximum pressure. See pump

data plate.

2. Worn Seal Rings.

2. Worn seal rings or cartridge valves may

need replacement (see Section 5.4).

3. Ruptured Liquifram™.

3. Replace Liquifram™ (see Section 5.3).

4. Incorrect stroke length.

4. Recalibrate Output (see Section

4.3.2)

5. Tubing run on discharge may be

too long.

5. Longer tubing runs may create frictional

losses sufficient to reduce pump’s pres-

sure rating. Consult factory for more

information.

6. Clogged Foot Valve strainer.

6. Remove Foot Valve strainer when

pumping slurries or when solution par-

ticles cause strainer to clog.

Failure to Run

1. Pump not turned on or plugged in.

1. Turn on or plug in pump.

2. EPU failure.

2. Disassemble pump and measure the

resistance of the EPU across the EPU

wires. Consult supplier or factory. (see

Section 5.8).

3. Pulser failure.

3. The pulser should be replaced if EPU

checks out OK. Consult supplier or

factory.

Excessive Pump

Output

1. Syphoning. (Pumping downhill

without a multi-function valve).

1. Move injection point to a pressurized

location or install an LMI 4-FV (see

Section 3.4).

2. Little or no pressure at injection

point.

2. If pressure at injection point is less than

25 psi (1.7 Bar), an LMI 4-FV should be

installed (see Section 3.4).

3. Excessive strokes per minute.

3. Replace pulser or resistor. Consult

factory.