4.3.3 Calibration in External Mode

1. Since pump output is governed by an external device such as Flowmeter-Pulser,

Liquitron

Controller, or 4-20 mA DC signal from an instrument with an LMI

Analog-to-Digital Converter, only the output per stroke may be calibrated.

2. With pump primed and discharge tubing connected to the injection point as it would

be in normal service, place Foot Valve Assembly in a graduated container with a vol-
ume of 1000 ml or more.

3. Switch pump to Internal mode with Speed Adjustment Knob set at 100% until air is

exhausted from suction line and pump head.

4. Switch pump OFF and refill graduate to a starting point.

5. Switch pump ON and count the number of strokes for exactly one minute, then switch

pump OFF.

6. Note volume pumped during the calibration period of one minute. Divide into this

the number of strokes to determine the volume of solution pumped per stroke.

Example: 720 ml in 240 strokes = 3.0 ml per stroke.

Multiply this by your expected stroke rate per minute, per hour or per day and compare

with desired output requirements.

7. Turn Stroke Adjustment Knob to your best estimate of required correction and repeat

calibration procedure.

It may be helpful

to decrease

the speed of

the pump in

order to count

the number

of strokes. For

accuracy count at

least 120 strokes.