beautypg.com

Advanced functions, 1 scanning all channels, 2 vox function – MIDLAND Pacific User Manual

Page 28: 3 keypad lock

background image

12

ENGLISH

6. Advanced functions

6.1 Scanning all channels

PACIFIC can automatically search for signals throughout the marine band by scanning, i.e. selecting

the channels in rapid sequence. When a signal is detected, the scanning pauses on that channel

and remains blocked for five seconds before automatically begins scanning again to give you the

chance to find other communication.

Press briefly the button

MON/SCAN to start scanning:

Press again

MON/SCAN to stop scanning. Your transceiver will go back to the channel from which

the scanning originally started.

Once you are tuned in the communication you were looking for, press

PTT to talk on the selected

channel.

PACIFIC will however remain in scanning mode (which is indicated by the flashing of the

channel on the display) and it is possible to start scanning again by pressing the / buttons. If you

press

PTT during scanning you can transmit on the channel from which the scanning started. The

/ keys allow you to change the direction of scanning (from lower channels to higher ones or vice

versa) and therefore to skip communications which are of no interest.

6.2 VOX Function

PACIFIC enables hands free conversations through VOX function. The degree of sensitivity of

VOX function can be adjusted to three different levels. You can enable VOX function with or without

accessories.

1) To activate

VOX function press the MENU button four times (except for CH75-76) and VOX will

appear on the display

2) Use the / keys to select:

A. High sensitivity

B. Middle sensitivity

C. Low sensitivity

3) Press

PTT to confirm or wait for 10 seconds

To disable

VOX function follow the instructions above and select option ‘oF’.

VOX has a better performance when used in conjunction with the optional accessories which plug

in the appropriate outlet. This will enable you to keep the microphone at constant distance from

your mouth and by holding the transceiver on the belt you can carry on working with your hands in

total freedom.

6.3 Keypad lock

You can lock the keypad of your transceiver and avoid pressing buttons accidentally. All buttons are

disabled with the exception of

MON (opening squelch), PTT, 16, MENU (removal of keypad lock).

To insert keypad lock:

1) Press three times the

MENU button (except for CH75-76); ‘Lc of’ will appear on the display and

the symbol will blink.

2) Using the / buttons select ‘on’.

3) Press

PTT to confirm or wait for 5 seconds.

To disable the keypad lock, press once the

MENU button and select ‘on’.