Communication Options
FLU-NetMan SNMP Adapter (Internal Network Card, external
model available) allows UPS management across a LAN using any
of the main network communication protocols—TCP/IP, HTTP and
network interface (SNMP). NetMan Plus enabled UPS integrate
easily into medium and large sized networks and provide reliable
communications between the UPS and management systems
employed.
FLU-MultiCOM1 MODBUS/JBUS (Internal Protocol Converter Card,
external model available) may be used to monitor the UPS using
the MODBUS/JBUS protocol on RS232 or RS485 serial lines. It can
also manage a second independent RS232 serial line that can be
used to connect to other devices such as the Netman Plus or a PC
using PowerShield software.
FLU-MultiCOM2 Serial/USB (Internal Serial/USB Card, external
model available) provides a UPS with an additional RS232 serial
interface or USB port. The USB port allows the UPS to communicate
with Apple Macintosh computers as well as Windows and Linux
operating systems.
FLU-Multi I/O (Internal Protocol Converter Card) has confi gurable
input and output signal contacts to allow UPS integration with
control systems. It can be used to connect two devices to a single
UPS serial communication port. It can also communicate using the
MODBUS/JBUS protocol on RS485 lines.
FLU-AS/400 (Communication Kit) has a single-level memory
management feature that makes it compulsory for the system
to be shutdown in a controlled and orderly manner. Without
UPS protection an AS/400 is not protected from mains failures.
A momentary loss of power can cause hardware damage, data
corruption and a lengthy reboot period.
FLU-Sensor Environmental Sensor Module: Monitors and records
environmental conditions as well as activities in protected areas
and at the premises where the UPS is installed. Environmental
sensors monitor and record environmental conditions and activities
within a designated building area. The sensors provide extensive
management and control, triggering cooling fans and locks
in response to changes in temperature and humidity. Remote
monitoring and control can be provided via the internet, SNMP
and the PowerShield
3
software. NetMan Plus can support up to
6 separate sensors. The environmental sensors are easy to install
and do not need a separate external power supply.
FLU-MultiPanel (Remote Monitoring Panel) device that can provide
a detailed UPS status overview in real time. It is compatible with all
UPS and can display values for UPS specifi c input and output supplies,
and battery set measurements. MultiPanel has a high-defi nition
graphical display and can report in seven languages: English, Spanish,
French, Chinese, German, Italian and Russian.
Includes three independent serial ports, one of which allows for UPS
monitoring via the MODBUS/JBUS protocol (on either an RS485 or
RS232 serial line). The others can be used with devices such as the
Netman Plus or a PC running PowerShield software.
FLU-PowerShield (Communicaiton Software) provides effi
cient,
user-friendly UPS management using bar chart displays to show
major operational information such as the input voltage, UPS load %
and batteries charge %. The software also provides detailed
information on fault conditions and UPS operating characteristics.
PowerShield
3
has been developed with a client/server architecture
that makes it fl exible and easy to use, and provides multi-lingual and
on-line support.
FLU-PowerGuard (Supervision Software) centralizes UPS
management using network interface (SNMP) communications.
It is ideal for data center managers and medium to large sized
networks. PowerNETGuard uses the RFC1628 standard Management
Information Base (MIB) and ensures standardized UPS management
wherever they are located.
Other Options
Top or Side Incoming Entry
A “side-car” cabinet expansion is off ered to accommodate top or
side incoming cable entry. Consult factory.
External Maintenance Bypass, 3 Breaker with Interlocks
Make-Before-Break, Line Up and Match wrap-around MBP for total
UPS isolation during maintenance or removal of the UPS.
Power Distribution Unit (PDU)
Line Up and Match Output Distribution Cabinet with (2) 42 Pole
Panelboards or Sub-Feed Circuit Breakers.
Basic Battery Monitoring
Battery monitoring system that monitors each battery and each string.
Battery Cycle Monitor
Monitors and records battery cycle data of each battery string.
Harsh Environment Enclosure
UPS and accessories mounted and pre-wired internal, with AC cooling
inside any NEMA (12, 3R, 4X) type enclosure.
Seismic Withstand Certifi cation
Site specifi c seismic certifi cation and documentation.
Start-Up Service, Preventative Maintenance Programs
A wide range of service programs are available to suit all
user requirements. Consult factory.
FirstLine
®
P
Up to Eight Units in Parallel
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS