WARNING
The washer-extractor should be connected to an individual branch
circuit not shared with lighting or other equipment.
Electrical Specifications HF304, IHF304, IHF075, CHF304, CHF075
304 liters / 75 pounds
Boiler Fed/Steam Heat
Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Recommended Circuit
Breaker (US-market)
AWG/mm2
kW Standard
Heating Elements
Full Load
Amps
Recommended
Circuit Breaker (US-
market)
AWG/mm2
US NON-US
US NON-US
N
440-480 50/60
3
3+PE
16
20
20
12/4.0
6x3 kW
42
50
50
8/10.0
P
380-415 50/60
3
3+N+PE 25
30
32
10/6.0
51
60
60
6/16.0
Q
200-240 50/60
3
3+PE
25
30
32
10/6.0
71
80
80
4/25.0
X
200-240 50/60
1/3
2/3+PE N/A N/A
N/A
N/A
N/A N/A
N/A
N/A
Alternative Electric Heat Options
N
440-480 50/60
3
3+PE
3x3 kW +
3x4 kW
46
50
50
8/10.0
P
380-415 50/60
3
3+N+PE
56
60
60
6/16.0
Q
200-240 50/60
3
3+PE
N/A N/A
N/A
N/A
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
N
440-480 50/60
3
3+PE
6x4 kW
51
60
60
6/16.0
P
380-415 50/60
3
3+N+PE
60
70
70
4/25.0
Q
200-240 50/60
3
3+PE
N/A N/A
N/A
N/A
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
N
440-480 50/60
3
3+PE
3x6 kW +
3x4 kW
59
70
70
4/25.0
P
380-415 50/60
3
3+N+PE
69
80
80
4/25.0
Q
200-240 50/60
3
3+PE
N/A N/A
N/A
N/A
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
Table 6