Warning – Alliance Laundry Systems HF150 User Manual
Page 33

4
33
WARNING
The washer-extractor should be connected to an individual branch
circuit not shared with lighting or other equipment.
Electrical Specifications HF234, IHF234, IHF055, CHF234, CHF055
234 liters / 55 pounds
Boiler Fed/Steam Heat
Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Recommended Circuit
Breaker (US-market)
AWG/mm2
kW Standard
Heating Elements
Full Load
Amps
Recommended
Circuit Breaker (US-
market)
AWG/mm2
US NON-US
US NON-US
N
440-480 50/60
3
3+PE
8
15
10
14/2.5
6x3 kW
34
40
40
8/10.0
P
380-415 50/60
3
3+N+PE 25
30
30
10/6.0
51
60
60
6/16.0
Q
200-240 50/60
3
3+PE
25
30
30
10/6.0
70
80
80
4/25.0
X
200-240 50/60
1/3
2/3+PE
25
30
30
10/6.0
N/A N/A
N/A
N/A
Alternative Electric Heat Options
N
440-480 50/60
3
3+PE
6x2 kW
25
30
32
10/6.0
P
380-415 50/60
3
3+N+PE
42
50
50
8/10.0
Q
200-240 50/60
3
3+PE
55
60
60
6/16.0
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
N
440-480 50/60
3
3+PE
3x3 kW +
3x2 kW
29
40
40
8/10.0
P
380-415 50/60
3
3+N+PE
47
50
50
8/10.0
Q
200-240 50/60
3
3+PE
63
70
70
4/25.0
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
N
440-480 50/60
3
3+PE
3x3 kW +
3x4 kW
38
50
50
8/10.0
P
380-415 50/60
3
3+N+PE
55
60
60
6/16.0
Q
200-240 50/60
3
3+PE
N/A N/A
N/A
N/A
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
N
440-480 50/60
3
3+PE
6x4 kW
42
50
50
8/10.0
P
380-415 50/60
3
3+N+PE
60
70
70
4/25.0
Q
200-240 50/60
3
3+PE
N/A N/A
N/A
N/A
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
Table 5