Magnum Venus Plastech CPR-2000 Cipher Gun User Manual
Page 10

Cipher Gun
4.
No Resin from the gun
·
Make sure trigger is pulling resin needle back / open
·
Check gun block for blockages
·
Check resin pump for proper operation (See resin pump manual)
5.
Resin leaking between fitting and gun block
·
Replace O-Ring (O-S-012)
Flush Problems
(reference drawing 5104-01-01)
1.
Solvent leaking from around flush button (inside flush body)
· Replace O-Ring (7301-13-008)* on valve button
2.
Solvent leaking from around flush neck (next to gun block)
· Replace Split Seal (5104-21-1)
3.
Solvent leaking from between the flush neck and flush body
· Replace Flush Valve Seal (5104-26-1)
4.
Solvent leaking around flush elbow fitting
· Tighten flush swivel Elbow Fitting (7701-6-1)
· Replace Nylon Seal (7304-3-1)
· Replace flush swivel Elbow Fitting (7701-6-1)
5.
Solvent leaking from Mix Housing / front of the gun
· Check for debris in seal area or damage to flush body
· Replace O-Ring (7301-3-007) on flush seal body
· Check for excessive pressure is flush system, set to no more than 80psi
General Problems
1.
Material leaking from around the mix chamber
· Replace Mix Housing Seal (O-S-016) or (5104-12-1)
· Replace Catalyst Injector Seal (5104-13-1)
2.
Air leaking from around poppet needle
· Tighten Retainer (54420-1) (caution do not over tighten, this will make the poppet
needle move slowly or not move at all.)
· Replace O-Ring (O-S-104A)
3.
Air leaking from around poppet valve body
· Tighten Poppet Valve Body (54440-1) into Gun Handle (54350-3)
4.
Air leaking from fitting on handle or to chopper
· Retainer (54420-1) may be too tight and holding valve open
· Check Poppet Assembly (MG-2031) for wear or damage
· Check Poppet Valve Body (54440-1) seat area for wear or damage
5.
Material leaking from around nozzle or nozzle cap
· Tighten Nozzle Cap (8704-4-1) (caution do not over tighten or you may damage
the Turbulent Mixer (5107-27-3)) Hand tighten only
· Check Turbulent Mixer (5107-27-3) for damage or wear
· Check front of Mix Housing (5104-20-1) for damage
6.
Trigger Action stiff or hard
· Check Trigger (54360-1) for damage
· Check Trigger Stud (54630-1) and Screw (00145) for damage, remove and
lubricate as needed.
· Check Needle Guides (53900-1) and Spring (04039-1) for damage, remove and
lubricate as needed
· Check Spring Retainer (54000-1) for wear or damage
· Check Needles (CPR-2005-01) and Needle Housings for hardened or sticky
material