Operating Controls

Note: Some options may not appear on your machine

1. Incoming Air Pressure Gauge.
Indicates incoming air pressure to the machine.


2. Counters.

i) Standard Counter

Records the number of pump strokes of the machine. Each digit represents 100
cc’s (0.1 litres) of resin displaced.

ii) Pre-Determined Counter (PDC)

The pre-determining counter contains two readouts. The upper readout displays

the machine output count during injection. The lower readout displays the preset
count entered by the operator. Each digit represents 100 cc's (0.1 litres) of resin
displaced.

To preset the counter, push white arrow lever on counter down and whilst
holding down - set the predetermined amount of strokes required with the

individual digit buttons and then release the white arrow lever. (Range 0-99.9
litres)