beautypg.com

Magnum Venus Plastech STAINLESS STEEL CHOP CHECK CCPLS-1000-SS User Manual

Page 7

background image

5.

Finish tightening the Intake Valve Packing Nut (CCPLS-1016-SS) into the Intake Valve
(CCPLS-1031). Slide it up against the Valve Stop (CCPLS-1014).


Final Assembly


1.

Apply a light film of red grease (6706-2-1) to the inside of both ends of Foot Valve
Housing (CCPLS-1019-SS).

2.

Slide the correct end of Foot Valve Housing (CCPLS-1019-SS) over the Priming Rod
and Intake Valve and onto the Cylinder (CCPLS-1008-SS).

3.

Apply a light film of red grease (6706-2-1) to O-Ring (0-V-145) and install onto Lower
Valve Seat (CCPLS-1018-SS).

4.

Install Lower Valve Seat (CCPLS-1018-SS) over the Priming Rod and into the Foot
Valve Housing (CCPLS-1019-SS).

5.

Install the four Tie Rods (CCPLS-1020) into the Outlet Body (CCPLS-1007-SS) and
tighten.

6.

Apply red grease (6706-2-1) to O-Ring (0-V-150) and install onto Priming Valve
Housing (CCPLS-1026-SS).

7.

Install the Priming Valve Housing (CCPLS-1026-SS) and O-Ring (0-V-150) over the
Priming Rod and into the Foot Valve Housing (CCPLS-1019-SS) and onto the Tie
Rods (CCPLS-1020). Align the notch in the Priming Valve Housing opposite the outlet
hole in the Outlet Body.

8.

Thread the four Hex Nuts (7201-12-8) onto the Tie Rods (CCPLS-1020) and tighten
them firmly against the Priming Valve Housing (CCPLS-1026-SS).

9.

Apply a thin film of red grease (6706-2-1) to Piston Seal (CCPLS-1024) and install
onto Priming Piston (CCPLS-1023-SS).

10. Adjust the Displacement Rod (CCPLS-1013-SS) in the pump so just the wrench flats

are exposed out of the Packing Nut (CCPLS-1006).

11. Place the Priming Piston (CCPLS-1023-SS) onto the Priming Rod (CCPLS-1027-SS).
12. Place onto Hex Cap Screw (F-HB-06F-12) one Backup Washer (CCPLS-1028-SS) the

Relief Washer (CCPLS-1025) and the last Backup Washer (CCPLS-1028-SS).

13. Apply a drop of Loctite to the threads of Hex Cap Screw (F-HB-06F-12) and thread it

into the end of the Priming Rod (CCPLS-1027-SS). Tighten only till the Priming Rod
(CCPLS-1027-SS) starts to spin. Use caution not to over tighten, the Relief Washer
may become damaged.