beautypg.com

Magnum Venus Plastech UltraMAX VHPC-2000 Series User Manual

Page 22

background image

VHPC-2000 Metering Pump Manual

Rev. 05/2012

Page | 22

17.

Carefully insert the Piston Rod assembly into the Cylinder (4101-2-1) screwing the Outlet
Body (4101-14-1) onto the cylinder threads.





18.

Align the Outlet Body (4101-14-1) so the outlet port is one hex flat to the left of the inlet port
of the Inlet Body (4101-7-1) See Fig. 4.1

19.

Tighten the Lock Nut up against the Outlet Body to secure it in place.



The Metering Pump assembly is complete.

NOTE

Screw the Outlet body down until you feel the O-Ring start to compress.

Offeset intake and outlet
ports one flat hex as
shown in figure.

Fig. 4.1