beautypg.com

Specifications – Liquid Controls SP712-2 REV. C User Manual

Page 2

background image

Sponsler, Inc.

SP712-2 Transmitter

pg 2

DOC#: MN-712-C


SPECIFICATIONS

Temperature:

Operating -40 to 85

°C

Storage -65 to 125

°C

Input Voltage:

Minimum = 7 V + (20mA X RL)
Maximum = 28 V + (4mA X RL)
Protected against polarity reversal

Signal Input:

Frequency 0-10 KHz
Amplitude 50 mV – 35 V sine or square wave
Sensitivity field adjustable
Impedance 50K

Analog Output

4mA @ 0 Hz, 20mA @ desired full scale frequency
Full scale range -- 100 Hz-10 KHz selectable
Response time -- 95% of change in 1 second
Linearity -- .3% F/S
Tempco -- < 2% of reading over entire temperature range

Features:

Mounts directly on flowmeter

Enclosure:

FM Approved, CSA Certified
Class I Groups B, C, D
Class II Groups E, F, G
Weight 1.7 lbs.


The SP712-2 is a 2-wire loop powered analog transmitter designed to linearly convert a
frequency input to an equivalent 4-20mA current output. When it incorporates with a turbine
flowmeter a current representation proportional to flow is obtainable. Data transmission in a
current format exhibits excellent noise immunity and the capability of long distance
transmission.

A full-scale frequency range of 100 Hz-10 KHz is selectable, via S1. The span adjustment
establishes the frequency point at which a 20mA output is achieved. The sensitivity adjustment
permits the SP712-2 to discriminate between a signal input and noise by increasing (CCW) or
decreasing (CW) the input signal amplitude necessary to process a valid signal. ‘Test’ S2 when
depressed, illuminates D1 if loop voltage and input signal both are present.

Installation of the SP712-2 requires only 2 wires because it is a true 2-wire transmitter: input
power and signal output utilizes the same wires.