beautypg.com

Installation & setup, 6 - setup dbmanager, 7 - setup office user rights – Liquid Controls FlightConnect Setup Guide User Manual

Page 7: 8 - establish communication, 9 - populate lcr 600 & dms databases

background image

7

InstallatIon & setup

#6 - setup dbmanager

After the master database is populated, the DBManager program can be set up. This involves registering all of the

LCR 600 and DMS units in the FlightConnect network, registering the units in the network with the correct master

database (more than one FlightConnect database can be created), and scheduling the LCR 600 and DMS database

files for updates (according to changes in the FlightConnect master database.

applicable manuals):

EM200-21 (DBManager) 500387

#7 - Setup Office User Rights

After DBManager is setup, users of the office software can be registered and assigned passwords in the Office User

Rights program, included in the DBManager software suite.

applicable manuals:

EM200-21 (DBManager) 500387

#8 - establish communication

- between offIce and lcr 600 & dms (& lcr-II) unIts

To establish communication between the office computer and the LCR 600 and DMS units in the network, the wireless

devices must be physically installed and the communication settings on the computer, LCR 600 (and DMS) units,

and the wireless devices must be aligned. The communication settings on the office computer can be set up with

LCP Setup program, included in the DBManager software suite. The LCR 600 and DMS software include settings

where the communication parameters can be adjusted. To install and set the communication settings for the wireless

devices, please refer to the literature for the device.
LC fueling systems can transfer data via a serial output to a device such as a Wifi adaptor, RF transceiver, or cell

modem. Cell modems enable long distance wireless data transmissions between LCR 600s and DMSs in the field

and computers in the office (cell modems require static IP addresses). Cell modems and service contracts must be

purchased separately from a cellular service provider. RF transceivers are designed for short, line-of-sight wireless

transmissions of data. Serial Wifi adaptors can be adapted to an

existing Wifi network within the customer framework. Wifi range is

typically very limited, but can be used if the Fueling System uploads

and downloads data from a location that is Wifi -enabled on the users

network. Liquid Controls does not provide Wifi adaptors, however

your distributor or IT Professional should be able to recommend

one. A USB Flash Memory Device can also be used to transfer data

between the DMS and computers in the office.

applicable manuals:

EM200-21 (DBManager) 500387
Wireless device manuals
EM250-10 (LCR 600 FlightConnect) 500390 or EM200-16 (DMS FlightConnect) 500323

#9 - populate lcr 600 & dms databases

The last step of FlightConnect installation is the population of the LCR 600 and DMS databases. Typically, the LCR

600 and DMS databases are automatically updated when they establish communication with the office,

FlightConnect Fueling Systems using DMS units can update the database (and transmit transaction with a USB

memory device) In order to populate the master database in FlightConnect systems using USB memory devices,

transfer the .501 and .slf files created by FlightConnect Edit onto the USB device. Take the USB to the DMS and use

the

retrieve entire database command on the DMS to pull all of the database files onto the DMS.

uSB flightConnect database updates

Please call Liquid Controls at 1-800-458-5262

or 847-295-1050 for assistance in specifying

cellular or Wifi components.

Cellular and Wifi Components

A complete RF solution is available from Liquid

Controls. Call Liquid Controls at 1-800-458-5262

or 847-295-1050 for more information

rf Components