Installation – Liquid Controls HMS3700 & HMS3770 Insertion Sensors LC Mag Insertion User Manual
Page 6

6
Installation
Model 3770 (installation in a non-pressurized system)
Step 1
Step 2
Cut the jacket (1"
diameter) to the proper
length “Z”.
Z = L - S -
1
/
8
D - 1.26"
NOTE: Refer to Step 6
for L dimension.
Recommended dimen-
sion of 1" thread.
Weld the jacket to the
pipe line.
Step 4
Step 5
Step 6
Step 3
Place the gasket on the
sensor.
Place the sensor in the
jacket.
Line up the connector
box longitudinally with
pipe line axis.
Tighten the lock nut with
wrench, maintaining the
alignment. Ensure that
the lock nut is tight
enough to create a
proper seal with the
gasket.
Sensor installed
Size
Nominal Diameter Range
L
Size 1
3" up to 20"
7"
Size 2
3" up to 40"
9.5"
Size 3
3" up to 80"
18"
Tighten the lock nut with
a wrench.
See also other documents in the category Liquid Controls Equipment:
- Gear Plate Selection Guide (24 pages)
- MS Meters (40 pages)
- MA4 Meter (32 pages)
- M-MA Meters (28 pages)
- HMS501, HMS600, HMS1000, HMS2400, HMS2500, and HMS5000 LC Mag IOM (8 pages)
- CIM100 (16 pages)
- Rate of Flow (4 pages)
- HML4-F1 - LCMag (40 pages)
- LCRII Install E3650-E3651 Series (40 pages)
- LCR-II Setup & Operation (60 pages)
- LCRII Menu Map (2 pages)
- LCR-II - Quick Reference (2 pages)
- LCR Install (24 pages)
- LCR Setup & Operation (60 pages)
- LCR 600 Install (36 pages)
- LCR600 Wiring Schematic (1 page)
- LCR 600 Setup & Op (68 pages)
- LCR 600 - Quick Reference (2 pages)
- FlightConnect 600 (52 pages)
- FlightConnect 600 QR (2 pages)
- LCR-II Installation E3655-E3656 (36 pages)
- LCRII E3651-E3656 Wiring Schematic (1 page)
- DMS Installation (20 pages)
- DMS Setup (84 pages)
- DMS Delivery (52 pages)
- DMS i1000 Quick Reference - DMS Delivery (2 pages)
- DMS Office (52 pages)
- DMS i1000 EZConnect Operators (36 pages)
- DMS i1000 Quick Reference - EZConnect (2 pages)
- EZConnect Office (44 pages)
- FlightConnect Office (36 pages)
- FlightConnect Setup Guide (8 pages)
- DB Manager (20 pages)
- POD (16 pages)
- Dual Meter Multiplexer (8 pages)
- Differential Pressure Transducer (12 pages)
- XL LED Display E1615_E1616_E1617_E1618 (20 pages)
- SCAMP (20 pages)
- WinHost Operation (44 pages)
- SP714-S2i (12 pages)
- HML110 IOM (31 pages)
- HML210 IOM - LCMag (44 pages)
- Sponsler T675 - Cryogenic System Register (54 pages)
- Sponsler IT400 Electronic Register (40 pages)