Each of the eight ports on the ULTRACOMM+8.PCI can be individually configured as an RS-232,
RS-422, or RS-485 interface. This is selectable via the port DIP-switch, each is labeled with its
port number.

Switch 1 (Silk M1) Switch 2 (Silk M0)

Mode Select

OFF

OFF

232

OFF

ON

422

ON

OFF

485 With Echo

ON

ON

485 No Echo


Typically, each end of the RS-485 bus must have line-terminating resistors (RS-422 terminates
at the receive end only). A 120-ohm resistor is across each RS-422/485 input in addition to a
1K-ohm pull-up/pull-down combination that biases the receiver inputs. Each switch allows
customization of this interface to specific requirements. Each switch position corresponds to a
specific portion of the interface. If multiple Ultra COMM+8.PCIe adapters are configured in an
RS-485 network, only the boards on each end should have switches T, P & P ON. Refer to the
following table for each position‟s operation:

Switch

Name

Function

3

T

Adds or removes the 120 ohm termination.

4

PU

Adds or removes the 1K ohm pull-up resistor in the RS-422/RS-485 receiver circuit

5

PD

Adds or removes the 1K ohm pull-down resistor in the RS-422/RS-485 receiver circuit

6

L

Connects the TX- to RX- for RS-485 two-wire operation.

7

L

Connects the TX+ to RX+ for RS-485 two-wire operation.

The RS-485 „Echo‟ is the result of connecting the receiver inputs to the transmitter outputs.
Every time a character is transmitted; it is also received. This can be beneficial if the software
can handle echoing (i.e. using received characters to throttle the transmitter) or it can confuse
the system if the software does not. An RS-485 „No Echo‟ option is selected by placing both
Mode switches (M0, M1) in the „On‟ position.