beautypg.com

Dsca, High performance signal conditioners, Dsca specifications – Impulse DSCA33 User Manual

Page 2: Ordering information

background image

High Performance Signal Conditioners

DSCA

Visit our website www.dataforth.com

135

DSCA

Specifications

Input

Signal Range

100mV to 300Vrms, 0 to 5Arms

Standard Frequency Range

45Hz to 1000Hz

Extended Frequency Range

1kHz to 20kHz

Impedance

1 M

±1% // <100pF (-01 thru -05), 0.10

(-06), 0.025

(-07)

Coupling

AC

Protection

Continuous (-01 thru -05)

480V peak AC & DC max

Continuous (-06 thru -07)

10 Arms max

Transient (-01 thru -05)

ANSI/IEEE C37.90.1

Transient (-06 thru -07)

See note 1

Output

Signal Range

See Ordering Information

Adjustability

±5% Zero & Span

Load Resistance

10k

max. (0-1mA models), 600

max. (0/4-20mA models)

Current Limit

1.4mA (0-1mA models), 30mA (0/4-20mA models),

8mA (0-5/10V models)

Protection

Short to Ground

Continuous

Transient

ANSI/IEEE C37.90.1

Ripple and Noise

<0.025% Span rms

Accuracy

(2) (3)

Sinusoid

50/60Hz

±0.25% Span

45Hz-1kHz

±0.25% Reading Additional Error

1kHz-20kHz

±0.75% Reading Additional Error

Non-Sinusoid

Crest Factor = 1 to 2

±0.05% Reading Additional Error

Crest Factor = 2 to 3

±0.15% Reading Additional Error

Crest Factor = 3 to 4

±0.30% Reading Additional Error

Crest Factor = 4 to 5

±0.40% Reading Additional Error

Vs. Temperature

±100ppm/°C

Isolation (Common Mode)

Input to Output, Input to Power

Continuous

1500Vrms max

Transient

ANSI/IEEE C37.90.1

Output to Power

Continuous

50VDC max

Response Time (0 to 99%)

<400ms

CMR (50 or 60Hz)

100dB

Power Supply

Voltage

19 to 29VDC

Current

60mA (V

OUT

), 80mA (I

OUT

)

Sensitivity

±0.0002%/%

Protection

Reverse Polarity

Continuous

Transient

ANSI/IEEE C37.90.1

Environmental

Operating Temp. Range

-40°C to +80°C

ATEX Group II, Category 3

-20°C to +40°C

Storage Temp. Range

-40°C to +80°C

Relative Humidity

0 to 95% noncondensing

Emissions EN61000-6-4

ISM, Group 1

Radiated, Conducted

Class A

Immunity EN61000-6-2

ISM, Group 1

RF

Performance A ±0.83% Span Error

ESD, EFT, Surge, Voltage Dips

Performance B

Mechanical Dimensions (h)(w)(d)

2.95" x 0.89" x 4.13" (75mm x 22.5mm x 105mm)

Mounting

DIN EN50022-35x7.5 or -35x15 rail

Module

DSCA33

Typical at T

A

=+25°C and +24V supply voltage

Model

Input (rms)

†

Output (dc)

†

DSCA33-01

0-100mV

2, 3, 4, 5, 6

DSCA33-02

0-1V

2, 3, 4, 5, 6

DSCA33-03

0-10V

2, 3, 4, 5, 6

DSCA33-04

0-150V

2, 3, 4, 5, 6

DSCA33-05

0-300V

2, 3, 4, 5, 6

DSCA33-06

0-1A

2, 3, 4, 5, 6

DSCA33-07

0-5A

2, 3, 4, 5, 6

Ordering Information

†

Modules can be ordered with other input/output ranges. Consult

factory for ordering details and specifications

Installation Notes:

1.) This Equipment is Suitable for Use in Class I, Division 2, Groups A, B,

C, D, or Non-Hazardous Locations Only.

2.) Warning - Explosion Hazard - Substitution of Components May Impair

Suitability for Class I, Division 2.

3.) Warning - Explosion Hazard - Do Not Disconnect Equipment Unless

Power Has Been Switched Off or The Area is Known to be Non-Hazardous.

NOTES:

(1) For 1 to 25 seconds the max allowable transient current rating is

2500 / (event time). For less than 1 second,

ANSI/IEEE C37.90.1 applies with a 0.05

load. For greater than 25 seconds, the 10A max continuous rating applies.

(2) For 10-100% rated span. Add 0.25% accuracy error (-02 thru -07), or 1.00% accuracy error (-01), for 0-10% Span measurements.

Accuracy includes nonlinearity, hysteresis and repeatability but not source or external shunt inaccuracy (if used).

(3) At standard 60Hz factory calibration. Consult factory for calibration at other frequencies.

2. 0V to +10V

NONE

DSCA33-01

3.

4 to 20mA

C

DSCA33-01C

4.

0 to 20mA

E

DSCA33-01E

5. 0V to +5V

A

DSCA33-01A

6.

0 to 1mA

B

DSCA33-01B

Output Range Part No. Suffix Example

†

††

†

†

Output Ranges Available