Dsca, High performance signal conditioners, Dsca specifications – Impulse DSCA36 User Manual
Page 2: Ordering information

High Performance Signal Conditioners
DSCA
Visit our website www.dataforth.com
139
DSCA
Specifications
Input Range Limits
0
Ω
to 10k
Ω
Input Protection
Continuous
240Vrms max
Transient
ANSI/IEEE C37.90.1
Sensor Excitation Current
260µA; 100
Ω
, 500
Ω
, 1k
Ω
Sensor
65µA; 10k
Ω
Sensor
Lead Resistance Effect
±0.01
Ω
/
Ω
; 100
Ω
, 500
Ω
, 1k
Ω
Sensor
±0.02
Ω
/
Ω
; 10k
Ω
Sensor
Output Range
See Ordering Information
Load Resistance (I
OUT
)
600
Ω
max
Current Limit
8mA (V
OUT
), 30mA(I
OUT
)
Output Protection
Short to Ground
Continuous
Transient
ANSI/IEEE C37.90.1
CMV, Input to Output, Input to Power
Continuous
1500Vrms max
Transient
ANSI/IEEE C37.90.1
CMV, Output to Power
Continuous
50VDC max
CMR (50Hz or 60Hz)
160dB
Accuracy
(1)
±0.03%
Conformity
±0.01%
Adjustability
±5% Zero and Span
Stability
Input Offset
±0.004
Ω
/°C; 100
Ω
, 500
Ω
, 1k
Ω
Sensor
±0.01
Ω
/°C; 10k
Ω
Sensor
Output Offset
±6ppm/°C (V
OUT
), ±20ppm/°C (I
OUT
)
Gain
±60ppm/°C
Output Noise, 100kHz Bandwidth
250µVrms (V
OUT
), 1µArms (I
OUT
)
Bandwidth, 3dB
3Hz
NMR
85dB at 60Hz, 80dB at 50Hz
Response Time, 90% Span
250ms
Open Input Response
+ Lead
Upscale
Lead
Non-deterministic
x Lead
Downscale
Power Supply
Voltage
15 to 30VDC
Current
25mA (V
OUT
), 55mA (I
OUT
)
Sensitivity
±0.0001%/%
Protection
Reverse Polarity
Continuous
Transient
ANSI/IEEE C37.90.1
Environmental
Operating Temp. Range
40°C to +80°C
ATEX Group II, Category 3
20°C to +40°C
Storage Temp. Range
40°C to +80°C
Relative Humidity
0 to 95% Noncondensing
Emissions EN61000-6-4
ISM, Group 1
Radiated, Conducted
Class A
Immunity EN61000-6-2
ISM, Group 1
RF
Performance A ±0.05% Span Error
ESD, EFT, Surge, Voltage Dips
Performance B
Mechanical Dimensions
2.95" x 0.89" x 4.13"
(h)(w)(d)
(75mm x 22.5mm x 105mm)
Mounting
DIN EN 50022 -35x7.5 or -35x15 rail
Module
Typical at T
A
=+25°C and +24V supply voltage
Ordering Information
DSCA36
Output Range
Part No. Suffix
Example
1. -10V to +10V
NONE
NA
2. 0V to +10V
NONE
DSCA36-01
3. 4 to 20mA
C
DSCA36-01C
4. 0 to 20mA
E
DSCA36-01E
Model
Input Range
Output Range
DSCA36-01
0 to 100
Ω
2, 3, 4
DSCA36-02
0 to 500
Ω
2, 3, 4
DSCA36-03
0 to 1k
Ω
2, 3, 4
DSCA36-04
0 to 10k
Ω
2, 3, 4
Output Ranges Available
Installation Notes:
1.) This Equipment is Suitable for Use in Class I, Division 2, Groups A, B, C, D, or Non-Hazardous Locations Only.
2.) Warning - Explosion Hazard - Substitution of Components May Impair Suitability for Class I, Division 2.
3.) Warning - Explosion Hazard - Do Not Disconnect Equipment Unless Power Has Been Switched Off or The
Area is Known to be Non-Hazardous.
NOTES:
(1) Includes nonlinearity, hysteresis and repeatability.