Description
Each DSCA38 strain gage input module provides a single channel of strain gage
input which is filtered, isolated, amplified, and converted to a high level voltage
output. Signal filtering is accomplished with a five-pole filter which is optimized
for step response. An anti-aliasing pole is located on the field side of the isolation
barrier, and the other four poles are on the system side. After the initial field-side
filtering, the input signal is chopped by a proprietary chopper circuit. Isolation
is provided by transformer coupling, again using a proprietary technique to
suppress transmission of common mode spikes or surges.
The DSCA38 can interface to transducers with a nominal resistance of 100
Ω
to 10k
Ω
. Strain gage excitation is provided from the module by a stable 10V or
3.333V source. This source is fully isolated, allowing the amplifier inputs to
operate over the full range of the excitation voltage. This feature enables the
module to be interfaced to other sensors requiring exctitation.
Module output is either voltage or current. For current output models a dedicated
loop supply is provided at terminal 3 (+OUT) with loop return located at terminal
4 (-OUT). The system-side load may be either floating or grounded.
Special input circuits provide signal input and excitation protection against
accidental connection of power-line voltages up to 240VAC and against
transient events as defined by ANSI/IEEE C37.90.1. Protection circuits are also
present on the signal output and power input terminals to guard against transient
events and power reversal. Signal and power lines are secured to the module
using screw terminals which are in pluggable terminal blocks for ease of system
assembly and reconfiguration.
The modules have excellent stability over time and do not require recalibration,
however, zero and span settings are adjustable up to ±5% to accommodate
Figure 1: DSCA38 Block Diagram
Features
Interfaces to 100
Ω
through 10k
Ω
Strain Gages
Industry Standard Output of either ±10V,
0-20mA, or 4-20mA
1500Vrms Transformer Isolation
ANSI/IEEE C37.90.1 Transient Protection
Input Protected to 240VAC Continuous
True 3-Way Isolation
Wide Range of Supply Voltage
100dB CMR
Fully Isolated Excitation Supply
±0.03% Accuracy
±0.01% Linearity
Easily Mounts on Standard DIN Rail
C-UL-US Listed
CE and ATEX Compliant
▲
situations where fine-tuning is desired. The zero adjustment can be used to offset
bridge imbalances. The adjustments are made using potentiometers located
under the front panel label and are non-interactive for ease of use.