beautypg.com

Impulse DSCA38 User Manual

Dsca38, Strain gage input signal conditioners, Dsca

background image

High Performance Signal Conditioners

DSCA

For information call 800-444-7644

142

DSCA38

Strain Gage Input Signal Conditioners

Description

Each DSCA38 strain gage input module provides a single channel of strain gage

input which is filtered, isolated, amplified, and converted to a high level voltage

output. Signal filtering is accomplished with a five-pole filter which is optimized

for step response. An anti-aliasing pole is located on the field side of the isolation

barrier, and the other four poles are on the system side. After the initial field-side

filtering, the input signal is chopped by a proprietary chopper circuit. Isolation

is provided by transformer coupling, again using a proprietary technique to

suppress transmission of common mode spikes or surges.
The DSCA38 can interface to transducers with a nominal resistance of 100

to 10k

. Strain gage excitation is provided from the module by a stable 10V or

3.333V source. This source is fully isolated, allowing the amplifier inputs to

operate over the full range of the excitation voltage. This feature enables the

module to be interfaced to other sensors requiring exctitation.
Module output is either voltage or current. For current output models a dedicated

loop supply is provided at terminal 3 (+OUT) with loop return located at terminal

4 (-OUT). The system-side load may be either floating or grounded.
Special input circuits provide signal input and excitation protection against

accidental connection of power-line voltages up to 240VAC and against

transient events as defined by ANSI/IEEE C37.90.1. Protection circuits are also

present on the signal output and power input terminals to guard against transient

events and power reversal. Signal and power lines are secured to the module

using screw terminals which are in pluggable terminal blocks for ease of system

assembly and reconfiguration.
The modules have excellent stability over time and do not require recalibration,

however, zero and span settings are adjustable up to ±5% to accommodate

Figure 1: DSCA38 Block Diagram

Features

• Interfaces to 100

through 10k

Strain Gages

• Industry Standard Output of either ±10V,

0-20mA, or 4-20mA

• 1500Vrms Transformer Isolation
• ANSI/IEEE C37.90.1 Transient Protection
• Input Protected to 240VAC Continuous
• True 3-Way Isolation
• Wide Range of Supply Voltage
• 100dB CMR
• Fully Isolated Excitation Supply
• ±0.03% Accuracy
• ±0.01% Linearity
• Easily Mounts on Standard DIN Rail
• C-UL-US Listed
• CE and ATEX Compliant

situations where fine-tuning is desired. The zero adjustment can be used to offset

bridge imbalances. The adjustments are made using potentiometers located

under the front panel label and are non-interactive for ease of use.