Dsca, High performance signal conditioners, Dsca specifications – Impulse DSCA39 User Manual
Page 2: Ordering information
High Performance Signal Conditioners
DSCA
Visit our website www.dataforth.com
145
DSCA
Specifications
Output Range
4 to 20mA or 0 to 20mA
0 to 20mA -20mA to +20mA
Over Range Capability
10%
*
5%
Output Compliance Voltage
(Open Circuit)
22VDC
*
±15VDC
Load Resistance Range
0 to 750
Ω
*
0 to 500
Ω
Output Protection
Continuous
240Vrms max
*
*
Transient
ANSI/IEEE C37.90.1
*
*
Input Range
±10V or 0V to +10V
0 to 20mA
±10V
Input Resistance
Normal
2M
Ω
<100
Ω
*
Power Off
2M
Ω
<100
Ω
*
Overload
2M
Ω
65k
Ω
*
Input Protection
Continuous
±35V max
75mA
*
Transient
ANSI/IEEE C37.90.1
*
*
CMV, Output to Input, Output to Power
Continuous
1500Vrms max
*
*
Transient
ANSI/IEEE C37.90.1
*
*
CMV, Input to Power
Continuous
50VDC max
*
*
CMR (50Hz or 60Hz)
110dB
*
*
Accuracy
(1)
±0.03% Span
*
±0.05%
Nonlinearity
±0.01% Span
*
*
Adjustability
±5% Zero and Span
*
*
Stability
Zero
±20ppm/°C
*
*
Span
±40ppm/°C
±50ppm/°C
*
Output Noise, 100kHz Bandwidth
4µArms
*
*
Bandwidth, 3dB
1kHz
*
*
NMR
100dB/Decade Above 1kHz
*
*
Response Time, 90% Span
475µs
*
*
Power Supply
Voltage
15 to 30VDC
*
19 to 29VDC
Current
65mA
*
*
Sensitivity
±0.0003%/%
*
*
Protection
Reverse Polarity
Continuous
*
*
Transient
ANSI/IEEE C37.90.1
*
*
Environmental
Operating Temp. Range
40°C to +80°C
*
*
ATEX Group II, Category 3
20°C to +40°C
*
*
Storage Temp. Range
40°C to +80°C
*
*
Relative Humidity
0 to 95% Noncondensing
*
*
Emissions EN61000-6-4
ISM, Group 1
*
*
Radiated, Conducted
Class A
*
*
Immunity EN61000-6-2
ISM, Group 1
*
*
RF
Performance A ±0.05% Span Error
*
*
ESD, EFT, Surge, Voltage Dips
Performance B
*
*
Mechanical Dimensions
2.95" x 0.89" x 4.13
*
*
(h)(w)(d)
(75mm x 22.5mm x 105mm)
Mounting
DIN EN 50022 -35x7.5
*
*
or -35x15 rail
Model
DSCA39-01, -02, -03, -04
DSCA39-05 DSCA39-07
Ordering Information
Model
Input Range
Output Range
DSCA39-01
0V to +10V
4mA to 20mA
DSCA39-02
-10V to +10V
4mA to 20mA
DSCA39-03
0V to +10V
0mA to 20mA
DSCA39-04
-10V to +10V
0mA to 20mA
DSCA39-05
4mA to 20mA
4mA to 20mA
DSCA39-07
-10V to +10V
-20mA to +20mA
Typical at T
A
=+25°C and +24V supply voltage
NOTES:
* Same specification as DSCA39-01, -02, -03, -04
(1) Includes nonlinearity, hysteresis and repeatability.
Installation Notes:
1.) This Equipment is Suitable for Use in Class I, Division 2, Groups A, B, C, D, or Non-Hazardous Locations Only.
2.) Warning - Explosion Hazard - Substitution of Components May Impair Suitability for Class I, Division 2.
3.) Warning - Explosion Hazard - Do Not Disconnect Equipment Unless Power Has Been Switched Off or The
Area is Known to be Non-Hazardous.