beautypg.com

Dsca, High performance signal conditioners, Dsca specifications – Impulse DSCA42 User Manual

Page 2: Ordering information

background image

High Performance Signal Conditioners

DSCA

Visit our website www.dataforth.com

149

DSCA

Specifications

Input Range

4-20mA

Input Resistance

Normal

<100

Power Off

<100

Overload

65k

Input Protection

Continuous

240Vrms max

Transient

ANSI/IEEE C37.90.1

Loop Supply Voltage

+20VDC

Isolated Excitation Protection

Continuous

240Vrms max

Transient

ANSI/IEEE C37.90.1

Output Range

See Ordering Information

Load Resistance (I

OUT

)

600

max

Current Limit

8mA (V

OUT

), 30mA (I

OUT

)

Output Protection

Short to Ground

Continuous

Transient

ANSI/IEEE C37.90.1

CMV, Input to Output, Input to Power

Continuous

1500Vrms max

Transient

ANSI/IEEE C37.90.1

CMV, Output to Power

Continuous

50VDC max

CMR (50Hz or 60Hz)

105dB

Accuracy

(1)

±0.03% Span

Nonlinearity

±0.01% Span

Adjustability

±5% Zero and Span

Stability

Offset

±6ppm/°C (V

OUT

), ±20ppm/°C (I

OUT

)

Gain

±40ppm/°C

Output Noise, 100kHz Bandwidth

500µVrms (V

OUT

), 2µArms (I

OUT

)

Bandwidth, –3dB

100Hz

NMR (-3dB at 100Hz)

100dB/Decade Above 100Hz

Response Time, 90% Span

5ms

Power Supply

Voltage

19 to 29VDC

Current

60mA (V

OUT

), 80mA (I

OUT

)

Sensitivity

±0.0002%/%

Protection

Reverse Polarity

Continuous

Transient

ANSI/IEEE C37.90.1

Environmental

Operating Temp. Range

–40°C to +80°C

ATEX Group II, Category 3

–20°C to +40°C

Storage Temp. Range

–40°C to +80°C

Relative Humidity

0 to 95% Noncondensing

Emissions EN61000-6-4

ISM, Group 1

Radiated, Conducted

Class A

Immunity EN61000-6-2

ISM, Group 1

RF

Performance A ±0.05% Span Error

ESD, EFT, Surge, Voltage Dips

Performance B

Mechanical Dimensions

2.95" x 0.89" x 4.13"

(h)(w)(d)

(75mm x 22.5mm x 105mm)

Mounting

DIN EN 50022 -35x7.5 or -35x15 rail

Ordering Information

Model

Input Range

Output Range

DSCA42-01

4mA to 20mA

0V to +10V

DSCA42-02

4mA to 20mA

2V to +10V

DSCA42-01C

4mA to 20mA

4 to 20mA

DSCA42-01E

4mA to 20mA

0 to 20mA

Module

DSCA42

NOTES:

(1) Includes nonlinearity, hysteresis and repeatability.

Typical at T

A

= +25°C and +24V voltage supply

Installation Notes:

1.) This Equipment is Suitable for Use in Class I, Division 2, Groups A, B, C, D, or Non-Hazardous Locations Only.
2.) Warning - Explosion Hazard - Substitution of Components May Impair Suitability for Class I, Division 2.
3.) Warning - Explosion Hazard - Do Not Disconnect Equipment Unless Power Has Been Switched Off or The

Area is Known to be Non-Hazardous.