beautypg.com

Scm7b, Scm7b specifications, Ordering information – Impulse SCM7B39 User Manual

Page 2

background image

SCM7B

Visit our website www.dataforth.com

81

Isolated Process Control Signal Conditioning Products

SCM7B

Specifications

Typical at 25°C and +24VDC

Output

Signal Range

(1)

4-20mA, 0-20mA

4-20mA

Effective Available Power

(1)

320mW

*

Protection

Continuous

120Vrms max

*

Transient

ANSI/IEEE C37.90.1

*

Current Limit

32mA

*

Input

Signal Range

1 to +5V, 0 to +10V

4-20mA

Bias Current

±1nA

N/A

Resistance

Normal

10M

270

Power Off

30k

min

>20k

Overload

30k

min

N/A

Protection

±35Vpeak (no damage)

±7.5Vpeak

Compliance

N/A

35VDC max

CMV (Input-to-Output)

Continuous

1500Vrms

*

Transient

ANSI/IEEE C37.90.1

*

CMRR (50 or 60Hz)

110dB

*

Accuracy

(2)

±0.03% Span typical,

*

±0.1% Span max

Nonlinearity

(3)

±0.01% Span typical,

*

±0.02% Span max

Stability (-40°C to +85°C)

Gain

±25ppm/°C

±50ppm/°C

Output Offset

±0.0035% Span/°C

±0.0045% Span/°C

Noise

Peak at 5MHz B/W

46µA

*

RMS at 10Hz to 100kHz B/W

4µA

*

Peak at 0.1Hz to 10Hz B/W

42nA

*

Open Output Loop Detection

Response

N/A

Input Resistance

> 20k

Detection Time

N/A

5ms

Frequency and Time Response

Bandwidth, -3dB

100Hz

*

NMR (-3dB at 100Hz)

80dB per decade above 100Hz

*

Step Response, 90% Span

5ms

*

Supply Voltage

18 to 35VDC

*

Current

(1)

56mA

*

Sensitivity

±0.0003%/%V

S

*

Mechanical Dimensions

2.13" x 1.705" x 0.605" max

*

(h)(w)(d)

54.1mm x 43.3mm x 15.4mm max

*

Environmental

Operating Temperature Range

-40°C to +85°C

*

ATEX Group II, Category 3

-20°C to +40°C

*

Storage Temperature Range

-40°C to +85°C

*

Relative Humidity

0 to 95% noncondensing

*

Emissions EN61000-6-4

ISM, Group 1

*

Radiated, Conducted

Class A

*

Immunity EN61000-6-2

ISM, Group 1

*

RF

Performance A ±0.5% Span Error

*

ESD, EFT, Surge, Voltage Dips

Performance B

*

Module SCM7B39-01,-02,-03 SCM7B39-04

Ordering Information

Model

Input Range

Output Range

NOTES:

* Same specification as SCM7B39-01, -02, -03

(1) Output Range and Supply Current specifications are based on maximum output load resistance. Maximum output

load resistance is calculated by P

E

/I

OUT

2

where P

E

is the Output Effective Available Power that guarantees output range,

accuracy, and linearity specifications. Output effective available power is independent of supply voltage.

(2) Accuracy includes the effects of repeatability, hysteresis, and linearity.

(3)

Nonlinearity is calculated using the best-fit straight line method.

SCM7B39-01

+1 to +5V

4 to 20mA

SCM7B39-02

0 to +10V

0 to 20mA

SCM7B39-03

0 to +10V

4 to 20mA

SCM7B39-04

4 to 20mA

4 to 20mA