beautypg.com

Scm9b, Isolated intelligent signal conditioning products, Specifications – Impulse SCM9B-1000_2000 Series User Manual

Page 2

background image

Isolated Intelligent Signal Conditioning Products

SCM9B

For information call 800-444-7644

102

Analog
• Single channel analog input.

• Maximum CMV, input to output at 60Hz: 500Vrms.

• Leakage current, input to output at 115Vrms, 60Hz: <2µArms.

• 15-bit measurement resolution.

• 8 conversions per second.

• Autozero & autocalibration—no adjustment pots.
Digital
• 8-bit CMOS microcomputer.

• Digital scaling, linearization and calibration.

• Nonvolatile memory eliminates pots and switches.
Digital filtering
• Small and large signal with user selectable time constants from 0 to 16 seconds.
Events counter
• Up to 10 million positive transitions at 60Hz max., filtered for switch debounce.
Digital inputs
• Voltage levels: ±30V without damage.

• Switching levels: High, 3.5V min., low, 1.0V max.

• Internal pull up resistors for direct switch input.
Digital outputs
• Open collector to 30V, 30mA max. load.
Alarm outputs
• HI/LO limit checking by comparing input values to down-loaded HI/LO limit values

stored in memory.

• Alarms: latching (stays on if input returns to within limits) or momentary (turns off if

input returns to within limits.)

Communications
• Communications in ASCII via RS-232C, RS-485 ports.

• Selectable baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400.

• NRZ asynchronous data format; 1 start bit, 7 data bits, 1 parity bit and 1 stop bit.

• Parity: odd, even, none.

• User selectable channel address.

• ASCII format command/response protocol.

• Up to 124 multidrop modules per host serial port.

• Communications distance up to 10,000 feet (RS-485).

• Transient suppression on RS-485 communications lines.

• Communications error checking via checksum.

• Can be used with "dumb terminal".

• Scan up to 250 channels per second.

• All communications setups stored in EEPROM.
Power
• Requirements: Unregulated +10V to +30VDC, 0.75W max (1500/2500, 2.0W max.)

• Internal switching regulator.

• Protected against power supply reversals.
Environmental
• Temperature Range: Operating –25°C to +70°C.

Storage –25°C to +85°C.

• Relative Humidity: 0 to 95% noncondensing.
1100/2100 Voltage Input Modules
• Voltage ranges: ±10mV, ±1V, ±5V, ±10V, ±100VDC.

• Resolution: 0.01% of FS (4 digits).

• Accuracy: ±0.02% of FS max.

• Common mode rejection: 100dB at 50/60Hz.

• Zero drift: ±1 count max (autozero).

• Span tempco: ±50ppm/°C max.

• Input burnout protection to 250VAC .
• Input impedance:

±1V input = 100M

min.

±5V input = 1M

min.

• 1 Digital input/Event counter, 2 Digital outputs.

Specifications

Typical at 25°C and nominal power supply unless otherwise noted

1200/2200 Current Input Modules
• Current ranges: ±1mA, ±10mA, ±100mA, ±1A, 4-20mADC.

• Resolution: 0.01% of FS (4 digits), 0.04% of FS (4-20mA).

• Accuracy: ±0.02% of FS, 0.04% of FS (4-20mA).

• Common mode rejection: 100dB at 50/60Hz.

• Zero drift: ±1 count max (autozero).

• Span tempco: ±50ppm/°C max. (±1A = ±80 ppm/°C max.)

• Voltage drop: ±0.1V max.

• 1 Digital input/Event counter, 2 Digital outputs.
1300 Thermocouple Input Modules
• Thermocouple types: J, K, T, E, R, S, B, C (factory set).

• Ranges: J = –200°C to +760°C

B = 0°C to +1820°C

K = –150°C to +1250°C

S = 0°C to +1750°C

T = –200°C to +400°C

R = 0°C to +1750°C

E = –100°C to +1000°C

C = 0°C to +2315°C

• Resolution: ±1°.

• Overall Accuracy (error from all sources) from 0 to +40°C ambient:

±1.0 °C max (J, K, T, E).

±2.5 °C max (R, S, B, C)(300°C to FS).

• Common mode rejection: 100dB at 50/60Hz.

• Input impedance: 100M

min.

• Lead resistance effect: <20µV per 350

.

• Open thermocouple indication.

• Input burnout protection to 250VAC.

• User selectable °C or °F.

• Overrange indication.

• Automatic cold junction compensation and linearization.

• 2 Digital inputs, Event counter, 3 Digital outputs.
1400 RTD Input Modules
• RTD types:

α

= .00385, .00392, 100

at 0°C,

.00388, 100

at 25°C.

• Ranges: .00385 = –200°C to +850°C.

.00392 = –200°C to +600°C.

.00388 = –100°C to +125°C.

• Resolution: 0.1°.

• Accuracy: ±0.3°C.

• Common mode rejection: 100dB at 50/60Hz.

• Input connections: 2, 3, or 4 wire.

• Excitation current: 0.25mA.

• Lead resistance effect: 3 wire - 2.5°C per

of imbalance.

4 wire - negligible.

• Max lead resistance: 50

.

• Input protection to 120VAC .

• Automatic linearization and lead compensation.

• User selectable °C or °F.

• 1 Digital output.
1450 Thermistor Input Modules
• Thermistor types: 2252

at 25°C, TD Series

• Ranges: 2252

= –0°C to +100°C.

TD = –40°C to +150°C.

• Resolution: 2252

= 0.01°C or F.

TD = 0.1°C or F

• Accuracy: 2252

= ±0.1°C.

TD = ±0.2°C

• Common mode rejection: 100dB at 50/60Hz.

• Input protection to 30VDC .

• User selectable °C or °F.

• 1 Digital input/ Event counter, 2 Digital outputs.