beautypg.com

Disposing of the product, Product technical specifications – Controlled Products Systems Group 318N User Manual

Page 13

background image

EN

English - 11

DISPOSING OF THE PRODUCT

This product is an integral part of the automation system,
and should therefore be disposed of together with it.
As for the installation operations, even at the end of this
product's life span, the dismantling operations must be car-
ried out by qualified experts.
This product is made up of various types of materials: some
can be recycled while others need to be disposed of. Find
out about the recycling or disposal systems envisaged by
your local regulations for this product category.
Important! – parts of the product could contain pollutants or
hazardous substances which, if released into the environment,
could cause harmful effects to the environment itself as well as
to human health.
As indicated by the symbol opposite,
throwing away this product as domestic
waste is strictly forbidden. So dispose of it
as differentiated waste, in accordance with
your local regulations, or return the prod-
uct to the retailer when you purchase a
new equivalent product.
Important! – the local applicable regulations may envisage
heavy sanctions in the event of illegal disposal of this prod-
uct.

PRODUCT TECHNICAL SPECIFICATIONS

WARNINGS: • All technical specifications are referred to a
room temperature of 20°C (± 5°C). • Nice S.p.a. reserves the
right to make any changes deemed necessary to the prod-
uct at any time while maintaining the same functions and
intended use. • The operating distance between transmitters
and receivers (range) is heavily influenced by other devices
operating in the vicinity at the same frequency (for example
headphones, alarm systems, etc.). In such cases, Nice can-
not provide any guarantee as regards the effective range of
its devices.

Decoding: “FloR”
Power supply: 12-24 V direct or alternating. Limits from

10 to 28 V

Power consumption when idle: 16 mA at 24 VDC
Power consumption with 2 relays active: 80 mA at 24

VDC

Reception frequency: 433.92 MHz
Sensitivity: better than 0.5

μV

No. of relays: 1 or 2 depending on the model
Normally open relay contact: max 0.5 A and 50 V SELV
Operating temp.: from –20° C to +55° C
Protection rating: IP 30
Dimensions and weight: 58 mm x 86 mm x H 22 mm; 55 g