3-17
Adjusting Gate Speed
The gate speed can be increased or decreased a ¼ foot per second from the operator’s default speed.
NOTE
Two options, one for OPEN SPEED the other for CLOSE SPEED, appear in the Installer
Menu. The steps involved in changing the open speed are shown below. The steps to set the
close speed are the same, you just need to access the CLOSE SPEED option.
To adjust the gate speed, take the following steps:
1. At a gate status display, press the MENU button
twice. The CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu.
Release the buttons and the LEARN LIMITS
display appears. It is the first item in the Installer
Menu.
3. Press NEXT until the OPEN SPEED (or
CLOSE SPEED) display appears. Select the
desired setting based on the operator type:
SlideSmart DC 15
0 = 0.75 ft/s
1 = 1.0 ft/s
(
Usage Class 3 & 4 only
)
2 = 1.25 ft/s
SlideSmart DC 10F
4 = 1.75 ft/s
(
The DC 10F is designed for
5 = 2.0 ft/s
Usage Class 3 & 4 sites only
) 6 = 2.25 ft/s
Note:Certain speeds are allowed only when the
operator’s Usage Class is set appropriately.
4. Use the SELECT and NEXT buttons to
navigate and change the speed setting on the
display.
5. To exit the Installer Menu, press the MENU
button. The gate status appears in the display
indicating you have returned to Run Mode.
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
1. Start at a gate status
display.
2. Access the User
Menu by pressing the
MENU button twice.
3. Access the Installer
Menu by
simultaneously
pressing the OPEN
and RESET buttons.
4. Use NEXT to
navigate to the menu
display. Change the
setting using the
SELECT and NEXT
buttons.
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
OS 5
OPEN SPEED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT