beautypg.com

Ram 30-30, Dip switch configuration, Dip switch "a" dip switch "b – Controlled Products Systems Group RAM3030 User Manual

Page 13

background image

RAM 30-30

11

RAMSET

www.ramsetinc.com

DIP SWITCh CONFIGURATION

Dip Switch "A" 1, 2 & 3;

AUTOMATIC TIMER TO CLOSE GATE

‘0’ is “OFF” ‘1’ is “ON”

Switch 1 2 3 Gate Open Duration:

1 1 1

60 seconds

1 1 0

45 seconds

1 0 1

30 seconds

1 0 0

15 seconds

0 1 1

10 seconds

0 1 0

05 seconds

0 0 1

00 seconds

0 0 0

disabled - command required to close

Dip Switch "B" 1; Not in use at this time.

Leave in the ‘Off’ position.

Dip Switch "B" 4,5,6 & 7; Not in use at this time.

Leave in the ‘Off’ position.

Dip Switch “A” 4 - 1/2 HP ERD

Dip switch A4 works with Dip switch B8

DIP A4 B8 Sensitivity
OFF OFF Most Sensitive

ON OFF 1/2 Hp—Medium Sensitivity

OFF ON

3/4 Hp—Medium Sensitivity

ON

ON

Least Sensitive

Dip Switch "B" 2; “PRE WARN”

Used with JP2 “Relay Connections”: pins 7 & 8.

Triggers a relay, for an alarm or light (not included), for 3 sec-

onds before the gate will move in any direction.

Sw.

Function:

ON Triggers the relay on JP2 pins 7 & 8 for 3 seconds.

OFF

Regular working conditions

Dip Switch "B" 3; “CONSTANT WARN”

Used with JP2 “Relay Connections”: pins 7 & 8.

Triggers a relay, for an alarm or light (not included), to be ac-

tive anytime the gate is in motion.

Sw.

Function:

ON Triggers the relay on JP2 pins 7 & 8 while the gate

is moving

OFF

Regular working conditions

Dip Switch “B” 8 - 3/4 HP ERD

Dip switch B8 works with Dip switch A4

DIP A4 B8 Sensitivity
OFF OFF Most Sensitive

ON OFF 1/2 Hp—Medium Sensitivity

OFF ON

3/4 Hp—Medium Sensitivity

ON

ON

Least Sensitive

DIP SWITCH "A"

DIP SWITCH "B"

“Intelligate” Control Board

Figure 13