Three pushbuttons are located under the dip switches for operation of the gate (see Figure 11). The

opening,

stop and closing buttons can be utilized to set limit switches and verify proper system operation when

installing or servicing an operator.
Opening:

Pressing this button will cause the gate to open.
Stop:

Pressing this button will cause the gate to

stop moving.
Closing:

Pressing this button will cause the gate to close.
Reset E.R.D. Board:

Push all three pushbuttons for approximately

5 seconds. All three L.E.D.’s should blink.

L.E.D.’s light up when opening,

Closing or Stopped

“Intelligate”

Control Board

PUShBUTTON CONTROLS

MASTER SLAvE INSTALLATION

Dip Switch “C”

MASTER / SLAVE INSTALLATION

Set Dip Switch (C8) "Slave Mode" to ON for

slave operator.

(RH) Right Hand operation requires Dip Switch

(C7) "Left/Right" to be ON.