Free gate loop layout illustration – Controlled Products Systems Group BGU-12-311 User Manual
Page 19

BGU
• BGU-D Barrier Gate Operator Installation Guide
- 17 -
P558 Revision X13 8-11-2011
Free Gate Loop Layout Illustration
2"
3/8"
LOOP
SEALANT
MULTIPLE TURNS
REFER TO LOOP
INSTALLATION NOTES
FOR DETAILS
USE RELIEF CUTS
AT CORNERS
TWIST WIRE FROM END OF
LOOPS BACK TO OPERATOR
AT LEAST SIX TIMES PER
FOOT
2" MAX.
THIS SYSTEM IS TYPICALLY USED AS AN ENTRANCE
OR EXIT IN CONJUNCTION WITH A CONTROLLED
ENTRANCE OR EXIT.
OPERATION OF FREE GATE
SYSTEM:
WHEN VEHICLE PASSES OVER OPEN
DETECTOR LOOP, THE ARM RAISES.
WHEN VEHICLE PASSES OVER AND OFF OF
RESET DETECTOR LOOP, THE ARM LOWERS.
FREE GATE LAYOUT
LOCATE BARRIER GATE EQUIPMENT 35' FROM ROADWAY
SO THAT APPROCHING VEHICLES ARE ABLE TO COMPLETE
RIGHT TURN BEFORE REACHING ACTUATING DEVICE.