3.2 Switch

Settings

The two DIP-switches located on the circuit board are used to program the operator to operate in
various modes and to turn on or off various operating features. Whenever a switch setting is
changed, power to the operator must be turned OFF and then turned back on for the new setting to
take affect. Check and review ALL switch settings prior to applying power to the operator.

SW 1 (UPPER SWITCH)

SWITCH FUNCTION SETTING

DESCRIPTION

1 Direction

OFF
ON

Changes open / close direction of operator.

2 Auto

Close

Timer

OFF
ON

Auto-close timer is OFF. Manual input required to close gate.
Auto-close timer is ON. Adjustable from 1-23 seconds.

3 Open

Loop

Output

OFF

ON

Switches logic-level output of EXIT loop port to terminal 4 and
removes terminal 4 as an open input.
Normal Setting

. Control board responds internally to loop

detector plugged into exit loop port.

4 & 5

Relay & LED

4-OFF 5-OFF
4-OFF 5-ON
4-ON 5-OFF
4-ON 5-ON

Relay activated and LED on when gate is FULL OPEN.
Relay activated and LED on when gate is NOT CLOSED.
Relay activated and LED on when gate is OPENING and OPEN.
Relay activated and LED on when gate is OPENING or CLOSING.

6 Solenoid

Lock

(see note 1)

OFF


ON

Normal setting

. Fail-safe logic. Lock engages only if attempt is

made to force gate open.
Fail-secure logic. Lock engages after each cycle.

7 Reverse

Stop

OFF

ON

Normal Setting

. Input to terminal 6 or reverse detector will

REVERSE gate during close cycle.
Input to terminal 6 will or reverse detector STOP gate during close
cycle.

8 Timer

Override

OFF
ON

Normal Gate Operation.
Opening gate will stop and begin to close as soon as all reversing
inputs (loops, beams) are clear regardless of the open position of
the gate.

SW 2 (LOWER SWITCH)

SWITCH FUNCTION SETTING

DESCRIPTION

1 Self

Test

(see note 2)

OFF

ON

Normal setting.

Run self-test – bench test only.

2 Open

Uphill

OFF

ON

Level – Normal Setting.

Gate opens uphill.

3 Slide

Gate

Overhead Gate

OFF


ON

Normal setting

. Must be in the OFF position for slide gate

operators.

4 Close

Uphill

OFF

ON

Level – Normal Setting.

Gate closes uphill.

NOTES:

1. Do not change the setting of this switch unless the solenoid/lock assembly has been

repositioned for the operation desired. Changing the setting of this switch without
physically changing the lock assembly will damage the operator.

2. Do not run the self-test while the gate operator is connected to the gate. This self-test

feature is designed for bench-testing only.