Once the operator is installed or if the control board is replaced, you will need to program
the control board for proper current sensing. The operator should be functional and the
open and close limits set.

1. Push and hold the LED ENABLE button for five seconds.

The “STOP” LED will blink indicating the board is in learn mode.

2. Cycle the gate three full times (must read open and close limit switches each cycle).

The “STOP” LED will now stay illuminated.

3. Adjust the current sensitivity pot to insure safe operation

The current sensitivity may be readjusted at any time without relearning the board.

Periodically check the current sensitivity for safe operation.