beautypg.com

Exp-2000 r – Controlled Products Systems Group EXP-2000 User Manual

Page 5

background image

1

Page 5 of 7

EXP-2000 R Electrical Connections

J1 Connections

2 - 8 to 16 VDC !

Power IN (+)

1 - Ground!

!

Power IN (-)

J2 Connections

8 - RS485 (+)!!

RS-485 Input

7 - RS485 (-)! !

RS-485 Input

6 - +5 VDC OUT!

5 Volt Power out

5 - Relay #4! !

Analog Input #4

4 - Relay # 3 !

Analog Input #3

3 - LED I/O! !

LED Signal Output

2 - Data 1 In! !

Wiegand Data 1 Input

1 - Data 0 In! !

Wiegand Data 0 Input

J3 Connections

12 - Relay #2!!

N.O. Contact

11 - Relay #2!!

Common

10 - Relay #2!!

N.C. Contact

9 - Relay #1! !

N.O. Contact

8 - Relay #1! !

Common

7 - Relay #1! !

N.C. Contact

6 - RS232 Output !

Serial Data OUT

5 - RS232 Input !

Serial Data IN

4 - Ground!

!

Wiegand/RS232 Ground

3 - Aux in!

!

Digital Input

2 -!

!

!

Not used

1 - !

!

!

Not used

DIP Switch Address Settings

ADDRESS! !

SWITCH!

!

!

!

12345678

1!

!

!

00000001

2!

!

!

00000010

3!

!

!

00000011

4!

!

!

00000100

5!

!

!

00000101

6!

!

!

00000110

7!

!

!

00000111

8!

!

!

00001000

9!

!

!

00001001

10!

!

!

00001010

11!

!

!

00001011

12!

!

!

00001100

13!

!

!

00001101

14!

!

!

00001110

15!

!

!

00001111!

16!

!

!

00010000

1 2 3 4 5 6 7 8

On

Off

Address settings for the EXP-2000

Cypress Suprex® systems will support different numbers
of additional EXP-2000 units depending upon the model
number. Refer to the specific documents for the
SPX-7400, SPX-5600, or SPX-7200 for maximum ratings.

Note:
To operate as a "Remote" unit, DIP Switch #2 must be Off.

*

J1

J2

J3

2- 8 to 16 VDC In
1- Ground

.

12- R2 N.O.
11- R2 Com

10- R2 N.C

9- R1 N.O.

8- R1 Com

7- R1 N.C.

6-RS232 output

5-RS232 Input

4-Ground

3- Aux in

2- Not used

1 - Not used

8-RS485 (+

)

7-RS485 (-)
6-+5 VDC Out
5- R4 in
4- R3 in
3-LED out
2-Data 1 in
1-Data 0 in

EXP-2000

R