CTEK SMARTPASS User Manual
Page 11

EN
EN • 13
SMARTPASS LAMP ERROR INDICATION
2
1
4
3
ExPLANATION
RECOMMENDATION
Service battery overheated
Check condition and/or installation
Too high current through or temperature
at internal relay. Too high Service bat-
tery charge current.
Check service battery. Reduce alternator size or
add one more D250S DUAL in parallel. Service bat-
tery bank too deeply discharged.
Too high current through or temperature
at internal relay. Too many consumers
connected at the same time.
Consider relocation of unit. Reduce power usage.
Too high current through or temperature
at internal relay. Too high current to
starter battery.
Starter battery problems, check battery.
Too high current through or temperature
at internal relay. Too many consumers
connected.
Relocate unit or reduce concurrent use of consumers.
Battery watch activated. Service battery
too low
Recharge Service battery
Steady lamp
Flashing lamp