beautypg.com

7charging program – CTEK MXS 3.8 User Manual

Page 3

background image

EN

EN • 5

1

VOLTAGE (V)

CURRENT (A)

ANALYSE

PULSE

DESULPHATION

SOFT START

BULK

ABSORPTION

15.8V

Increasing voltage

to 14.4V

0.8A

3.8A until 12.6V

Increasing voltage

to 14.4V

3.8A

1

6

Limit:

Max 20h

Max 8h

3 minutes

10 days

Charge cycle restarts

if voltage drops

Charge cycle restarts

if voltage drops

15.8V

15.8V

3.8A until 12.6V

0.8A until 12.6V

Increasing voltage

to 14.7V

3.8A

14.4V

Declining current

14.4V

Declining current

14.7V

Declining current

Checks if voltage

drops to 12V

Checks if voltage

drops to 12V

Checks if voltage

drops to 12V

13.6V

3.8A

13.6V

0.8A

13.6V

3.8A

12.7V‒14.4V

3.8‒1.9A

12.7V‒14.4V

0.8‒0.3A

12.7V‒14.7V

3.8‒1.9A

Max 8h

2

3

4

5

FLOAT

7

CHARGING PROGRAM

STEP 1 dESULPHATION

Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the

lead plates of the battery restoring the battery capacity.
STEP 2 SOFT START

Tests if the battery can accept charge. This step prevents that charging proceeds with

a defect battery.
STEP 3 BULK

Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION

Charging with declining current to maximize up to 100% battery capacity.

STEP 5 ANALYSE

Tests if the battery can hold charge. Batteries that can not hold charge may need to

be replaced.
STEP 6 FLOAT

Maintaining the battery voltage at maximum level by providing a constant voltage

charge.
STEP 7 PULSE

Maintaining the battery at 95–100% capacity. The charger monitors the battery volt-

age and gives a pulse when necessary to keep the battery fully charged.