7charging program – CTEK MXS 3.8 User Manual
Page 3
EN
EN • 5
1
VOLTAGE (V)
CURRENT (A)
ANALYSE
PULSE
DESULPHATION
SOFT START
BULK
ABSORPTION
15.8V
Increasing voltage
to 14.4V
0.8A
3.8A until 12.6V
Increasing voltage
to 14.4V
3.8A
1
6
Limit:
Max 20h
Max 8h
3 minutes
10 days
Charge cycle restarts
if voltage drops
Charge cycle restarts
if voltage drops
15.8V
15.8V
3.8A until 12.6V
0.8A until 12.6V
Increasing voltage
to 14.7V
3.8A
14.4V
Declining current
14.4V
Declining current
14.7V
Declining current
Checks if voltage
drops to 12V
Checks if voltage
drops to 12V
Checks if voltage
drops to 12V
13.6V
3.8A
13.6V
0.8A
13.6V
3.8A
12.7V‒14.4V
3.8‒1.9A
12.7V‒14.4V
0.8‒0.3A
12.7V‒14.7V
3.8‒1.9A
Max 8h
2
3
4
5
FLOAT
7
CHARGING PROGRAM
STEP 1 dESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the
lead plates of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents that charging proceeds with
a defect battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need to
be replaced.
STEP 6 FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage
charge.
STEP 7 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery volt-
age and gives a pulse when necessary to keep the battery fully charged.