beautypg.com

Ready to use, Charging programs, Error lamp – CTEK MXS 3.8 User Manual

Page 2: Power lamp

background image

4 • EN

BATTERY SIZE (Ah)

TIME TO 80% CHARGEd

2Ah

2h

8Ah

8h

20Ah

5h

60Ah

15h

80Ah

20h

REAdY TO USE

The table shows the estimated time for empty battery to 80% charge

CHARGING PROGRAMS

Settings are made by pressing the MODE-button. After about two seconds the charger

activates the selected program. The selected program will be restarted next time the

charger is connected.

The table explains the different Charging Programs:

Program

Battery

Size (Ah)

Explanation

Temp range

1.2–14Ah

Small battery program

14.4V/0.8A

Use for smaller batteries.

-20°C–+50°C

(-4ºF–122ºF)

14–130Ah

Normal battery program

14.4V/3.8A

Use for WET batteries, Ca/Ca,

MF, GEL batteries and many

AGM batteries.

+5°C–+50°C

(41ºF–122ºF)

14–130Ah

Cold weather program

14.7V/3.8A

Use for charging at low tempera-

tures and for power AGM batter-

ies like Optima and Odyssey.

-20°C–+5°C

(-4ºF–41ºF)

ERROR LAMP

If the error lamp is lit, check the following:

1. Is the chargers positive lead connected to the battery´s

positive pole?

2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in STEP 1, 2 or 5?

Restart the charger by pressing the MODE-button. If charging is still

being interrupted, the battery...

STEP 1: ...is seriously sulphated and may need to be replaced.

STEP 2: ...can not accept charge and may need to be replaced.

STEP 5: ...can not keep charge and may need to be replaced.

POWER LAMP

If the power lamp is lit with a:

1. STEAdY LIGHT

The mains cable is connected to the wall socket.

2. FLASHING LIGHT:

The charger has entered the energy save mode. This happens if the

charger isn´t connected to the battery in 2 minutes.