S.A.F.E. DIAGNOSTIC MESSAGES

Open S.A.F.E. Probe Fault: This message indicates that the fire suppression probe is either not connected or
is damaged.

Shorted S.A.F.E. Probe Fault: This message indicates that the fire suppression probe is damaged or the
wiring is shorted.

Open S.A.F.E. Valve Fault: This indicates that the water valve coil is open, the resistance of the coil is too
high, or that it is not connected to the control.

Shorted S.A.F.E. Valve Fault: This indicates the water valve coil is shorted or the wiring to the valve is
shorted.

Water Not Connected: This indicates that there is no water pressure at the water valve. This will occur if
water is not connected to dryer or if there is low water pressure in the water line coming to the dryer. This could
also be a defective pressure switch or wiring to the pressure switch.