BATTERY SIZE (Ah)

TIME TO 80% CHARGEd

20Ah

2h

50Ah

5h

100Ah

10h

200Ah

20h

REAdY TO USE

The table shows the estimated time for empty battery to 80% charge

CHARGING PROGRAMS

Settings are made by pressing the MODE-button. After about two seconds the charger

activates the selected program. The selected program will be restarted next time the

charger is connected.

The table explains the different Charging Programs:

Program

Battery

Size (Ah)

Explanation

Temp range

20–300Ah

Normal battery program

14.4V/10A. Use for WET batteries,

Ca/Ca, MF and for most GEL batteries

-20°C–+50°C

(-4ºF–122ºF)

AGM

20–300Ah

AGM battery program 14.7V/10A

Use for AGM batteries.

-20°C–+50°C

(-4ºF–122ºF)

RECOND

20–300Ah

Recond program 15.8V/1.5A

Use to return energy to the empty

WET and Ca/Ca batteries. Recond

your battery once per year and after

deep dischare to maximise lifetime

and capacity. The Recond program

adds STEP 6 to the

normal battery

program. Frequent use of the Recond

program may cause water loss in the

batteries and reduce service life of

electronics. Contact your vehicle and

battery supplier for advice.

-20°C–+50°C

(-4ºF–122ºF)

20–300Ah

Supply program 13.6V/10A

Use as 12V power supply or use for

float maintenance charging when 100%

capacity of the battery is required.

Supply program activates step 7 without

time or voltage limitation.

-20°C–+50°C

(-4ºF–122ºF)

ERROR LAMP

If the error lamp is lit, check the following:

1. Is the chargers positive lead connected to the batterys

positive pole?

2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in STEP 1, 2 or 5?

Restart the charger by pressing the MODE-button. If charging is still

being interrupted, the battery...

STEP 1: ...is seriosly sulphated and may need to be replaced.

STEP 2: ...can not accept charge and may need to be replaced.

STEP 5: ...can not keep charge and may need to be replaced.

TEMPERATURE SENSOR

The MXS 10 is equipped with an external temperature sensor. The tempera-

ture sensor is attachable. If so, the charger will compensate voltage accor-

ding to ambient temperature. Activated temperature sensor will be indicated

by a lit temperature sensor indicator lamp.

WARNING!

The spark protection on the battery charger

is disabled during SUPPLY program.

POWER LAMP

If the power lamp is lit with a:

1. STEAdY LIGHT

The mains cable is connected to the wall socket.

2. FLASHING LIGHT:

The charger has entered the energy save mode. This happens if the

charger isn´t connected to the battery in 2 minutes.

20014905E MXS 10, Manual EU, Print file 004.indd 4

2011-10-11 08:50:50