Installation, Cabinet installation, Pcb link positions – Cleveland Motion Controls WebPro Winder Tension ControllerMWP-12664 REV BA User Manual
Page 7: Webpro winder tension controller

AO-70171
6
Revision BA
WebPro Winder Tension Controller
Installation
The following parts are supplied:-
1. Controller, with software loaded for the application but requiring commissioning by the user.
2. Two keyhole mounting brackets.
3. Cable gland to be fitted to the rear cover and header connector kit for encoders.
4. Cabinet, if ordered.
5. Manual (this document).
Transducers and cables may also be supplied to complete the system
The Controller should be installed using 'best practice' and in accordance with all relevant specifications.
The Controller must be installed in a dry, non-hazardous location. A panel cutout 8.27in (210mm) wide x
7.01in (178mm) high is required. The Controller is 3.94in (100mm) deep, additional space for the cables
is needed.
The Controller is retained by two mounting brackets. Remove the four screws securing the mounting
brackets to the Controller. Insert the Controller into the cut out in the panel. Refit the four screws, attach
the mounting brackets to the Controller and tighten the two nylon screws to retain the Controller.
Cabinet Installation
The cabinet has rear mounting holes for M8 fixing.
When the Controller is supplied as a cabinet version the
mains supply is terminated inside the cabinet on a three
way terminal block. The incoming mains cable should be
securely fastened by the gland plate cord grip.
PCB Link Positions
The links LK1 to LK5 MUST be in the proper positions for
correct operation. It may be found more convenient to position the links before connecting the Controller.
LK1 Excitation Voltage Position B
This gives 5.6V for Cleveland-Kidder transducers
LK1 Excitation Voltage Position A
This gives 10V for ACDF and foil transducers
LK2 and LK3
IN
For Cleveland-Kidder transducers to complete the bridge
LK2 and LK3
OUT
For full bridge transducers, the bridges are complete
LK4 and LK5 Gain
Position A
Normal gain for Cleveland-Kidder transducers
LK4 and LK5 Gain
Position B
High gain for Cleveland-Kidder transducers
LK4 and LK5 Gain
Position C
Normal gain for ACDF and foil transducers
LK4 and LK5 Gain
Position D
High gain for ACDF and foil transducers
The High gain positions providing three times the normal gain are used if the transducers are oversized
and there is insufficient signal level for accurate calibration.
CUT OUT
210 X 178
155
380
ENTRY GLAND PLATE
LOCK
6 in.
(155mm)
2 in. (50mm)
11.
8 in
(300m
m
)
8.27 in. x 7.01 in.
(210x178mm)
15 in.
(380mm)
LK4
6
1 6
1
HD2
HD1
TB1
1
TB3
LK2
1
3
2
4
5
6
TB2
L
E
N
3
1
2
5
4
1
D
D
A
B
C
A
B
C
LK5
LK1
A B
VR1 ZERO
VR2 SPAN
TB4
LK3
TB5
3
2
4
5
6
8
7
9 10
14
11 12 13
15
10
9
6
5
4
2 3
8
7
13
12
11