Brake, Utilization, Emag 4h – Cleveland Motion Controls Brake EMAG 4 User Manual
Page 2: Specifications

0
0,1
0,2
0,3
0,4
0,5
0
1
3
4
5
2
34
49
7
2
Ø
8
h
0
7
Ш
3
9
Ш
0
4
1
Ш
3
5
Ш
2
5 E9
Ø 17 H8
3
1
J
3,
9
1
39,5
+ 0,1
- 0
Utilization
• Mounting must be made without any stress.
Lubricated for life (other internal lubrication not allowed).
The shaft should be lubricated upon assembly, to prevent seizing.
• Low DC current power supply for coil.
• The standard device is designed for horizontal shaft orientation,
and a minimal speed of 60 RPM. Maximum speed is 3000 RPM.
(without exceeding the max. heat dissipation capability)
• For Engineering application, please contact our technical support
• In normal use, the outside temperature of the device can increase up to 100°C,
without damage.
0
4
x
3
M
s
w
er
c
s
3
0
6
Ø
n
o
°
0
2
1 t
a
m
N
e
u
qr
o
T
Current A
Brake
EMAG 4H
Nominal torque
5
N.m
ft.lbf 4
Minimal torque
0,1
N.m
ft.lbf 0.07
Rated current DC
A
0.50
Rotor inertia
99.10
-6
kg.m
2
lb.ft
2
23 10
-4
Weight
2
kg
lb
4.41
Heat dissipation
W *
continuous sustained
100
Specifications
* Heat dissipation is the mechanical power (P = cw) maximum allowable.
Coil resistance - 20°C
Ohm 24
Cleveland Motion Controls, Inc.
7550 Hub Parkway
Cleveland, Ohio 44125
phone: 216.524.8800 or 800.321.8072
fax: 216.642.2199
www.cmccontrols.com