beautypg.com

4 environmental requirements, 5 operating conditions, 6 emc technical ratings – Cleveland Motion Controls Classic Series DIN Rail Amplifier Non-Isolated MWI-13466 REV CA User Manual

Page 7: 7 emission specifications, Nvironmental, Equirements, Perating, Onditions, Echnical, Atings

background image

MAN-13466

R

EV

CA C

LASSIC

S

ERIES

N

ON

-I

SOLATED

A

MPLIFIER

P

AGE

7

OF

26

1.4 E

NVIRONMENTAL

R

EQUIREMENTS

Requirement

Description

Enclosure

IP20
NEMA 1

Operating temperature

0 to 55 degrees C
32 to 132 degrees F

Humidity

Non-condensing
85% at 55 degrees C
85% at 132 degrees F

Altitude

1000 meters
3300 feet

Atmosphere

Non-flammable, non-corrosive and dust free

Storage temperature range

-25 to 80 degrees C
-13 to 176 degrees F

Transport temperature range

-25 to 80 degrees C
-13 to 176 degrees F

1.5 O

PERATING

C

ONDITIONS

Condition

Classic Series DIN Rail amplifier

Installation category

Category III

Pollution Pollution

Degree

2

Input supply

Earth (Ground) referenced

Protection Enclosure

mounted

1.6 EMC

T

ECHNICAL

R

ATINGS

Port

Phenomenon

Test Standard

Level

Test Standard

Enclosure

ESD

EN 61000-4-2

8KV AD, 1KV CD

EN 61326:1997

Enclosure

RF Field

EN 61000-4-3

10V/m,1 Khz AM

EN 61326:1997

Transducer Leads

Fast Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

Output Leads

Fast Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

Transducer Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

Output Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

** AC Power Line

Surge

EN 61000-4-5

+/-2KV L to PE
+/-1KV L to L

EN 61326:1997

** AC Power Line

Voltage Dips

EN 61000-4-11

+/-0.5 Cycle
100%

EN 61326:1997

** These specifications apply when using CMC power supply, MWI-13418.

1.7 E

MISSION SPECIFICATIONS

Port

Phenomenon

Test Standard

Level

Generic Standard

Enclosure

Radiated

EN 61326: 1997

Class A

EN 61326:1997


The levels of performance indicated are achieved when the Classic Series DIN Rail Amplifier is
installed by using the instructions and specifications outlined in this document.