Above ground base install model 920 pg 7, Above ground, base installation – model 920 – King Technology Perform-Max Feeders User Manual
Page 7

Apply pipe thread tape or
sealant to the threaded end
of both hose adapters.
Screw adapters into each end of Perform-Max. Hand
tighten. Finish tightening by turning 1 to 2 revolutions
with wrench. DO NOT OVER TIGHTEN.
Attach the filter section of flex
hose to one hose adapter and
the return section of flex hose
to the other hose adapter with
clamps and tighten with
screwdriver.
Above Ground, Base Installation – Model 920
TOE NIPPLE
CHECK
VALVE
BUSHING
HOSE
CLAMP
HOSE
ADAPTER
HOSE
CLAMP
HOSE
ADAPTER
TO POOL
1 1/2" OR 1 1/4"
FLEX HOSE
1 1/2" x 1 1/2" x 1 1/4"
HOSE ADAPTER
HOSE
CLAMP
FILTER &
PUMP
The Perform-Max should always be installed
between the filter and pool (or between
heater and pool if applicable).
TO POOL
PUMP
FILTER
7
MATERIALS NEEDED
Two
Hose
Clamps
Corrosion Resistant
Check Valve
RECOMMENDED
OPTION
1 1/2" Male Adapter
(slip x MPT)
When installing with hard
PVC pipe, use either a
female adapter on the
outside port threads or
a male adapter on the
inside port threads.
#10 x 1 1/4" Phillips Pan
Head Screws with
Washers
2” Female
Adapter
(slip x
FPT)
1.
2.
3.
4.
5.
TOOLS NEEDED
Installing a corrosion resistant check valve is recommended for the
protection of pool equipment especially a heater, from chemical
corrosion.
Pipe Thread
Tape or
Sealant
Two Hose Adapters
1 1/2" x 1 1/2" x 1 1/4"
Two Sections of
of 1 1/2" Flex Hose (one
provided with filter)
Screwdriver
Pipe Wrench
If you prefer to mount this unit
there is an additional base part
available - PN# 01-22-1480.
Mount using Phillips Pan head
screws.