Quick Start Guide INSTEON In-LineLinc On/Off Module with Sense
Typical Wiring (without Sense)
NOTE: If you do not plan on using the Sense wire, be
sure to deactivate it before completing installation.
To deactivate the Sense wire:
1) Press and hold the Set button until it beeps (3
seconds).
The In-LineLinc Status LED should begin
blinking.
2) Double-tap the Set button.
In-LineLinc should beep and its Status LED
should stop blinking and turn on solid if the
load is off or turn off if the load is on.
Wiring with Sense
Motion Sensor Floodlight shown as an example
*Setup modes will automatically time out after 4 minutes.
Page 2 of 2
Rev. 03-15-2012
Complete Instructions, Troubleshooting and Tech Support
Owner’s Manual:
http://wiki.smarthome.com/index.php?title=2475S2_Manual
Call: INSTEON Support Line at 800-762-7845
Linking In-LineLinc as an INSTEON Controller
Note: The following instructions will allow you to use the In-LineLinc Sense wire to activate other INSTEON devices.
1) Set In-LineLinc to linking mode* by pressing and holding the Set button until it beeps (3 seconds).
The In-LineLinc Status LED will begin blinking.
2) Set the responder to the state you wish to activate from In-LineLinc.
3) Press and hold the responder’s Set button for 3 seconds.
In-LineLinc should double-beep and its LED should stop blinking and turn on solid.
4) Confirm that linking was successful by tapping the On/Off buttons on In-LineLinc.
The responder should respond appropriately.
Linking In-LineLinc as an INSTEON Responder
1) Set your INSTEON controller to linking mode.* (For most controllers, press and hold the Set button for 3
seconds or an On/Scene button for 10 seconds.)
2) Press and hold the Set button on In-LineLinc until it double-beeps (3 seconds).
The In-LineLinc Status LED should flash once and then turn on solid if the load is off or turn off if the
load is on.
3) Confirm that linking was successful by tapping the button you just linked to on the controller.
The load connected to In-LineLinc should respond appropriately.
SmartLabs Limited Warranty – SmartLabs warrants to original consumer of this product for a period of 2 years from date of purchase, this product will be
free from defects in material & workmanship & will perform in substantial conformity with its Owner's Manual. Warranty shall not apply to defects caused by
misuse or neglect.
Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012
SmartLabs, 16542 Millikan Ave., Irvine, CA 92606, 1-800-SMARTHOME (800-762-7846)