beautypg.com

INSTEON DIN Rail Dimmer - 2452-222 (US), 2452-422 (EU), 2452-522 (AUS/NZ) Quick Start User Manual

Page 2

background image

2452-222/2452-422/2452-522 Rev. 12/14/2012 5:42 PM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see www.insteon.com)
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 866-243-8022



d) Perform the step that applies

For single momentary: slowly tap set button four times

LED will continue blinking green

For dual momentary: slowly tap set button five times

LED will start double-blinking green

To switch back to latching: slowly tap set button six times

LED will start blinking green

e) Once the mode is selected, press and hold set button until it double-beeps

LED will stop blinking and turn green if load is on or red if load is off

Make DIN Rail a Responder

Control DIN Rail from another INSTEON device:

1)

Press and hold controller button until it beeps

Controller LED will start blinking

2)

Press and hold DIN Rail paddle top or bottom to adjust load to desired brightness

(or off) when scene is activated

Connected load will respond appropriately

3)

Press and hold DIN Rail set button until it double-beeps

Controller will double-beep and its LED will stop blinking

4)

Test by tapping controller button on and off

Connected load will return to the state set in step #2

Make DIN Rail a Controller

Use DIN Rail to control other INSTEON devices:
1) Press and hold DIN Rail set button until it beeps

DIN Rail LED will start blinking green

2) Turn responder on (or any other state such as on 50% or even off)
3) Press and hold responder set button until it double-beeps

DIN Rail will double-beep and its LED will stop blinking

4) Test by tapping DIN Rail paddle top and bottom

Responder load will respond appropriately
Din Rail LED will turn green when load is on and red when load is off

Assign an X10 Address
1)

Press and hold DIN Rail set button until it beeps

DIN Rail LED will start blinking green

2)

Send the X10 address 3 times (with or without commands)

Example: A1-A1-A1-AON or A1-AON-A1-AON-A1-AON
DIN Rail will double-beep and its LED will stop blinking

3)

Test by sending X10 on and off commands

Load will turn on and off

Owner’s Manual and Tech Support

Visit:

http://www.insteon.com/support

for complete manual, online tech support and latest product documents.

Call: INSTEON Support Line at 866-243-8022

FCC and IC Warnings

This device complies with FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes: (1) l'appareil ne doit
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement.


CAUTION - To reduce the risk of overheating and possible damage to other equipment do not install to control a receptacle, a motor-operated appliance, a fluorescent lighting fixture, or a
transformer-supplied appliance.

Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres materiels, ne pas installer pour commader une
prise, un appareil a moteur, une lampe fluorescente ou un appareil alimente par un transformateur.

DIN Rail

(Responder)

Controller

DIN Rail

(Controller)

Responder