In Box 2 (Traveler box)
12) Connect SwitchLinc bare wire to ground
13) Connect SwitchLinc white wire to neutral
14) Cap SwitchLinc red wire
15) Connect SwitchLinc black wire to same color
traveler from Box 1 that you connected to
line along with same color traveler wires
leading to Box 3
16) Cap the last unused traveler wire(s)
In Box 3 (Load box)
17) Connect SwitchLinc bare wire to ground
18) Connect SwitchLinc white wire to neutral
19) Connect SwitchLinc red wire to load
20) Connect SwitchLinc black wire to line
traveler from Box 2 (Line traveled from Box 1
through 2 into 3 usually black)
21) Cap unused traveler wire
22) With LEDs on left, gently place SwitchLincs
into wall boxes and screw in place
23) Turn power back on
SwitchLincs and connected load will
turn on
24) Add all SwitchLincs to a group. See
“Groups”
22) Verify all SwitchLincs are working properly
by tapping each on and off
All SwitchLincs and the connected load
will remain in synch
25) Reinstall wallplates
Local Control
Follow these instructions to control the connected light/load (as well as any responders) from the
SwitchLinc paddle.
1
If neutral is not available in this box; use other unused traveler from Box 1 to carry neutral to Box 2. Label and mark any differently colored wire being connected to neutral with
a piece of white tape to flag it as neutral.
Connected Light (and Responders)
Paddle
Tap
Press and hold
Double-tap
Top
On
(ramped)
Brighten
(until release)
On
(instant)
Bottom
Off
(ramped)
Dim
(until release)
Off
(instant)
Tap for ON, press and hold to brighten