beautypg.com

Clear-Com Tempest2400 User Manual

Page 2

background image

Select a location for the

BaseStation and/or Remote Transceiver

1

3

System range and performance may be greatly reduced if antennas are

blocked or obstructed.

Always operate the system with antenna attached, locate as high as
possible and away from all obstructions (especially metal).

Never use antenna on the back of the BaseStation when the BaseStation
is in a rack

When using the Whip (omni-directional) antenna, always locate it as close
as possible to the center of the coverage area.

When using a directional antenna, always aim it in the same general
direction.

When remotely locating antenna, use only high quality 50 ohm, low loss,
RF cable (30 ft max).

Remote antenna location of up to 1500 ft using standard CAT-5 wiring
may be achieved using the optional Tempest Remote Transceiver.

» This must be a point to point connection
» Plug your Transceiver into the BaseStation prior to powering ON the

BaseStation

Connect the AC power cord to the BaseStation and to the AC wall outlet.

Turn the BaseStation on via the front panel ON/OFF switch.

The first time you power up the BaseStation, you will be prompted
to “select an authorized band for your location”.

There are seven RF bands that use different parts of the 2.4GHz
spectrum.

Scroll to an appropriate band for your location and press Enter to
select.

Press MENU to return to the operational screen.

Band 1 is appropriate for most, but not all, locations worldwide (US is

band 1). Some countries require that you use a limited portion of the

2.4GHz band. It is the user’s responsibility to ensure that you select a

band that is permitted for use in your location.

Power ON the BaseStation

Selecting the RF band

MHz

Band Start

End

Wide Avoid 802.11b/g

1

2400 2480

80

None

2

2400 2450

50

11

3

2423 2473

50

1

4

2431 2480

49

1,2

5

2400 2428

28

7,8,9,10,11

6

2423 2450

27

1,11

7

2453 2480

27

1,2,3,4,5,6,7

4

From the front of the BaseStation, follow the steps below :
1. Press MENU (Main Menu)
2. Press 1 (BaseStation Settings).
3. Scroll to 7 (Tech Menu) and press ENTER. A Tech Menu warning

message will appear - Press ENTER to proceed.

4. Press ENTER or 1 (Radio Configuration).
5. Press ENTER or 1 (Network Number) and select a network other than

zero and press ENTER to save setting.

» If you have multiple BaseStations, ensure that you select a different

Network Number for each BaseStation.

» Collocated BaseStations should be in the same Network Number

Group.

6. Press MENU to return to previous menu; press 2 (Lockout Key) and

select a lockout key other than 255 and press ENTER to save setting.

7. Press MENU repeatedly until you get back to the Operational screen.
8. Power the BaseStation OFF; wait 10 seconds and power the BaseStation

ON again.

Changing the Default RF

Configuration

9

9

Tempest 2400 operates in the 2400 to 2483 MHz frequency
spectrum and should never be synced with 900 MHz models.

9

9

Tempest® BaseStations and BeltStations are shipped with a
default RF configuration. It is highly recommended that you change
your system from the default to ensure proper RF performance
especially in the presence of other Tempest systems.

9

9

A BeltStation must be paired with a BaseStation for any
communication to take place. Pairing should be done AFTER the
default RF configuration is changed on the BaseStation.

9

9

Charge the BeltStation batteries prior to starting set-up.

Important things you need to know

2