3 - 1
SPECIFICATIONS
Relay
Type
1 Form C
Quantity
6
Contact Max. Volts
24 volts DC
Contact Max. Cur.
1 ampere continuous,
(2 amperes peak at 24 volts DC
(resistive load)
DC Isolation
10 mega-ohms
Module Power Supply Requirements
Voltage Required
8 – 10 volts DC
Current Required
150 mA max (25 mA per relay
when active)
Connectors
Relay Contacts
2 ea. DB-9M
Matrix Connection
2 ea. RJ-45 each
Indicators and Controls
LED Indicators
6 Green (1 ea. per relay)
1 Yellow (Frame Data)
Pushbutton Switches
6 (1 Test Pushbutton per relay)
Wiring Requirements
Maximum line lengths for connection to Matrix Frame
Matrix Frame to interface frame shall be less than 15 feet ( 5 meters)
Maximum line length between interface frame inputs 6 inches (15 cm)
Operating Environment
Temperature
0 and 70° C (32 -150° F)
Package Dimensions
Height
5 1/16" (129 mm)
Width
1 3/8" (35 mm)
Depth
9 5/32" (233 mm)
Weight
.35 LBS (.15 kg)
Notice About Specifications
While Vitec Group Communications makes every attempt to maintain
the accuracy of the information contained in its product manuals, that
information is subject to change without notice. Performance
specifications included in this manual are design-center specifications
and are included for customer guidance and to facilitate system
installation. Actual operating performance may vary.
3