beautypg.com

Physical installation, Description of connectors, Headset connector (front panel) – Clear-Com MS-704 User Manual

Page 24: Panel mic connector (front panel), Belden cable (4 individually shielded pairs)

background image

M S - 7 0 4 / R M - 7 0 4 F O U R - C H A N N E L M A I N / R E M O T E S T A T I O N S

2 - 8

Figure 2-9: Proper power wiring of a system powered by a single MS-704

PHYSICAL INSTALLATION

You can install the MS-704 and RM-704 units in a standard equipment rack, or
you can use them as stand-alone units sitting on a table or desk. For installing in
an equipment rack, the units require 3.5 in. (8.89 cm or 2RU) of rack space. The
stations are10.5 in. (26.67 cm) in depth and require at least 2.5 in. (6.35 cm)
clearance in the rear to clear connectors and cables.

DESCRIPTION OF CONNECTORS

HEADSET CONNECTOR (FRONT PANEL)

Note:

The following is a description of a recommended headset.

Mic Type --- Dynamic, see technical specifications for details

Wiring:

Pin 1 --- Mic common
Pin 2 --- Mic hot
Pin 3 --- Headphone common
Pin 4 --- Headphone hot

CAUTION: Do not tie pin #1 and pin #3 together.

PANEL MIC CONNECTOR (FRONT PANEL)

Two plug-in panel microphones are available for use on the MS-704 and
RM-704. The GM-9 is 9 in. (22.86 cm) long and GM-18 is 18 in. (45.72 cm)

PROGRAM IN

ANNOUNCE OUT

AUX

On

Off

On

Off

Term

On

Off

On

Off

CHANNEL A

CHANNEL C

CHANNEL D

Output: 30V 1.2A Continuous, 2A Peak

ELECTRIC SHOCK DO NOT

FIRE OR SHOCK HAZARD DO NOT
EXPOSE THIS EQUIPMENT TO RAIN

TO PREVENT

TO PREVENT

WARNING:

OR MOISTURE.

CAUTION:

REMOVE COVER. NO USER
SERVICEABLE PARTS INSIDE.
REFER TO QUALIFIED SERVICE
PERSONNEL.

MS-704

HOT MIC/IFB

RM-704

HOT MIC/IFB

CHANNEL A

CHANNEL C

CHANNEL D

CHANNEL B

PROGRAM IN

ANNOUNCE OUT

AUX

RM-704

MS-704

CHANNEL B

Belden Cable
(4 individually shielded pairs)

Class 2 Wiring