6.1 General description
6 Electronic control panel
The control panel is powered by 230V on the L-N terminals, with a 50/60 Hz frequency.
The command devices and accessories run on 24V. Moreover, the total accessories cannot run on more than 40W.
The panel controls a service light to light up the service area; at each opening it lights up for 2 minutes and 30 seconds.
The V0670 card may be connected to operate the automation kit with emergency batteries (see the technical documentation
attached).
The card automatically controls the following functions:
1) amperometric detection of obstructions during opening, closing and during slow down phases (with adjustable sensitivity);
2) automatic closing (adjustable);
3) working cycle (80”);
4) open-stop-close-stop command
5) reopening dueing the closing phase of the photocells.
in the closing phase: invert the direction of movement
until completely opened;
Warning! After three, consecutive inverted
cycles, the door will stay open excluding automatic
closing function: to close the door, use the remote
control or a command button.
in the opening phase: invert the direction
of movement until completely closed;
FUSES
Protection
Fuse type
Motor
7,5A
Circuit board (line)
1,6A
Accessories
3,15A
Command devices (control unit)
315mA
LIGHTS
Service
E17 24V 25W