6 programming decelerations – CAME BX-78 Kit User Manual
Page 15
![background image](/manuals/332457/15/background.png)
6.6 Programming decelerations
So as to fully meet the compliance requirements established by European Standards EN 12445 and EN 12453 on matters concerning
maximum impact forces, BX-74/78 is set up for deceleration at 50 cm from the opening and closing endpoints. When installing all you
need to do is program the gate operation as follows:
Before proceeding, set all the DIP SWITCHES to OFF (10-way Dip Switches)
a) - Set Dip Switch 4, 7, 8 and 9 to ON (10-way Dip Switch) and Dip Switch 3 e to OFF (4-way dip-switch, optical reader);
b) - press CH1 until the red LED starts fl ashing (after about 3 secs). After which, the gate will fully open and close.
c) - when the led stays on, this means the programming procedure is fi nished;
d) - reset the DIP SWITCHES to the previous setting, which is determined by the selection of functions (see parag. 6.4 on p. 14).
b)
d)
c)
The decelerated gate operation speed may be changed by simply pressing CH1 (to reduce it) or CH2 (to increase it) while the
operator is decelerating.
With BX-74/78 you can change the function of the Re-closing Partial
Stop during opening, which is connected on 2-C3.
To activate it, do the following:
a) - Set Dip Switch 1 and 4 on ON;
b) - press CH1: the red LED will start to fl ash;
c) - when the LED stays lit up (after about 5 secs) this means that
the procedure is fi nished;
d) - reset the DIP SWITCHES to the previous setting, which is
determined by the selection of functions (see parag. 6.4 on p. 14).
N.B.: to go back to the default selection, follow the same procedure but
press CH2.
a)
c)
b)
d)
CH2 = Partial Stop (default)
CH1 = Re-closing during opening (to select)
6.7 Modifying the Re-closing Partial Stop during opening
3 4 5 6 7 8 9 1 0
3 4 5 6 7 8 9 1 0
3 4 5 6 7 8 9 1 0
3 4 5 6 7 8 9 1 0
“DIP-SWITCH 10”
“DIP-SWITCH 4”
NOTE: When the card is initially activated, the PROG LED will fl ash rapidly, and in so doing signalling that the card is not programmed;
once programmed the LED will remain off.
To exclude decelerations, set Dip Switch 10 to ON.
If power is cut off during gate closure operation and decelerations have been activated, once the power comes back on, the operator
always and for safety reasons, will perform a full, decelerated opening and closing cycle.
a)
Pa
g.
1
5
15
-
Ma
n
u
al
c
od
e:
11
9
B
U
5
6
11
9
B
U
5
6
ve
r.
1
.0
1.
0
0
1
/2
0
0
8 © C
A
M
E c
an
celli auto
mati
ci
s.p
.a. -
Th
e d
ata an
d i
nf
or
m
ati
on r
ep
orte
d i
n thi
s i
n
stall
ati
on
manu
al ar
e s
u
sc
ep
tib
le to c
h
ang
e at an
y time an
d with
ou
t o
b
lig
ati
on
o
n C
A
M
E cancelli auto
mat
ici s.p
.a. to n
ot
ify u
ser
s.
ENGLISH